The flow rate can be adjusted at the flow control valve. Pump with switch on immediately after plug is
plugged into power supply.
The bearing, shaft and shaft sleeve will wear, and perish and/or break over time. As a result, it will sound
noisy. You can then change the impellor part when necessary.
●How to change:
① Unplug the power, ② Open the impeller chamber, replace the old impellor with the new one. Taking
care to replace all the parts and not break the (ceramic) shaft.
To avoid possible electric shock, special care should be taken when handling this product.
In each of the following situations, do not attempt repair unit by yourself. Discard the appliance:
★ If the appliance shows any sign of abnormal water leakage, immediately unplug unit from the power
source.
★ Do not operate any appliance if it has a damaged cable or plug, if it is malfunctioning or it has been
dropped or damaged in any manner.
★ To avoid the possibility of the plug getting wet, please ensure that the power supply is sufficiently far
away from the unit before plugging into power supply.
★If the plug or receptacle does get wet, don't unplug the cord. First disconnect the fuse or circuit
breaker that supplies power to the appliance. Then unplug and examine.
Model No
Voltage Frequency
DF-330
DF-440
DF-880
DF-1050
DF-1770
DF-2050
DF-3050
DF-5050
The DF2050, 3050 and 5050 can be used in and out of water. i.e. They are amphibious.
Imported by: East Dune Trading (Pty) Ltd
51 Gerhardus Street.
Strijdom Park.
Randburg, 2194
Use
Maintenance
Caution
Technical Specifications
Power
Max Head
5w
0.8m
8w
1m
16w
1.3m
22w
1.6m
40w
2.5m
55w
2.5m
85w
3.5m
70w
5.6m
+27 11 4668250
www.waterhouse.co.za
Max Flow
Working Conditions
400LPH
600LPH
Fresh Water
800LPH
1000LPH
1800LPH
2000LPH
Fresh&Salt Water
3000LPH
8000LPH