ACCESSORIES
Polyester filter &
3 x dust bags
Activac 1 exhaust filter
Dustpan installation kit
18
Utility inlet
TECHNICAL PROBLEMS
The unit will not start:
1. Check the circuit breaker on your electrical panel.
2. Check the circuit breaker of the unit. (Image D1)
3. Check the 24 volt circuit:
To check the 24 volt circuit, proceed as follow;
• Establish the contact between the two ports of a wall mounted air
inlet valve with a piece of metal (ex. coin (Image E)). If the system
starts, the suction hose is defective. See your dealer.
• If the system does not start check the 24 volt wires on the unit
(Image D2); Establish the contact between the two screws of the
24V circuit plate using a piece of metal (ex. Screw driver (Image F)).
If the unit starts, the 24 volt wire is either cut OR unplugged from
one of the wall mounted air inlet valves.
• If the system still do not start after steps 1, 2 and 3, the printed
circuit is defective. Call your dealer.
The unit will not stop:
Check the 24 volt circuit as follows;
• Disconnect one of the two 24 volt wires on the unit (Image D2). If
the unit stops, the two wires are in contact somewhere in the circuit
OR a wall mounted air inlet valve is defective.
• If the unit does not stop, the printed circuit is defective.
Call your dealer.
NOTE: If you notice a vibration coming from the motor, call your dealer.
Image D
24V wires(2)
Coin
Image E
Breaker / Fuse (1)
Image F
19