Dramm CHEMDOSE CD-120 Benutzerhandbuch - Seite 7

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Farbspritzgerät Dramm CHEMDOSE CD-120 herunter. Dramm CHEMDOSE CD-120 13 Seiten.

Dramm CHEMDOSE CD-120 Benutzerhandbuch
O
:
PERATION
1. Switch the three position switch from "off" to "on".
2. Determine the amount of solution desired per shot and set the inner timer dial to
the corresponding time setting. Use the chart below (figure 1) or on the machine to
determine this setting.
3. Set the outer dial to the desired interval time. The scale on this timer may be
changed for longer or shorter times by using a paper clip as shown below (figure 2).
This timer is factory preset to seconds.
4. Press the green button for one shot. Press the red button to begin interval dosing.
Press the red button a second time to stop interval dosing.
5. Keep track of the number of shots per full charge. After 16,000 shots, the volume
will decrease from the pump even though the machine will appear to dose correctly.
6. After application, thoroughly clean machine by triple rinsing the tank and flush-
ing the hose with clean, hot water. Make sure that clean water flows through the
entire length of the hose.
F
1
IGURE
Time in
Seconds
Volume
in ML
Volume
in OZ
F
2
IGURE

Operation

0.1
0.2
0.3
14
23
32
0.47
0.78
1.08 1.42 1.69 2.00
•Using a paper clip or another similar object you
can change the scale for the Chemdose spray
cycle and delay. Each square around the dial
corresponds to the nearest display.
•You can change the Seconds (SEC) to Minutes
(MIN) or Hours (HRS).
•You can also change the multiplier of x0.1 to x1.
0.4
0.5
0.6
0.7
42
50
59
67
2.27 2.57
Chemdose Manual
0.8
0.9
1.0
76
82
91
2.77 3.08
9