This power sprayer troubleshooting section shows how to diagnose and resolve problems that
may occur in the course of normal operation. If you experience a problem, take the steps
indicated for the applicable diagnosis. When you can't determine the cause of a problem or
if you have any difficulty, please feel free to contact your nearest dealer or this company's
sales office. Please have the following information ready: 1. Model designation 2. Serial
number 3. Description of problem (What happened? What were you doing when it
happened? What were the conditions when it happened?) For items marked with *, please
request adjustment or repair from your nearest dealer or from this company's sales office.
Do not change the setting of the screw that is under the cap on the top of the
WARNING:
pressure regulator knob. This screw absolutely must not be changed, since that will raise the
pressure above rated specifications, damage the machine, and possibly cause injury.
P
ROBLEM
• Suction is Low or Absent
–Up to Suction Port
–Suction & Pressure
Parts (Cylinder Part)
–Pressure Regulator
Part
• Pressure Will Not Increase
–Suction & Pressure
Part
–Pressure Regulator
Part
Hydra SprayTrax Manual

Troubleshooting

C
AUSE
• Suction strainer is blocked
with debris
• Suction hose is damaged or
crooked
• Suction hose connector
gasket is bad
• Connection is bad
• Debris is stuck in inlet or
discharge valve
• Inlet or discharge valve is
assembled improperly
• Inlet or discharge valve is
damaged or worn
• Discharge valve spring is
damaged
• Piston packing is damaged
• O-ring is damaged
• Seal & packing are
damaged
• Pressure regulator valve
lever in is RUN position
• Pressure regulator is stuck
• Insufficient liquid supplied to
intake
• Pressure regulator valve ball
or valve seat damaged
• Pressure regulator valve rod
is bad
• Pressure regulator valve
spring bad
• Pressure regulator valve
spring is damaged or weak
18
R
EMEDY
• Clear and clean
• Repair or replace
• Repair or replace
• Connect properly
• Clean
• Assemble properly
• Repair or replace
• Replace
• Replace
• Replace
• Replace
• Return lever to START position
• Disassemble & clean
• Diagnose under (1)
• Replace
• Adjust or replace
• Repair or replace
• Replace