Draper 220V Signature V Series Installations- und Betriebsanleitung - Seite 2

Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Projektionsfläche Draper 220V Signature V Series herunter. Draper 220V Signature V Series 2 Seiten. Electric

Draper 220V Signature V Series Installations- und Betriebsanleitung
220V Signature/Series E & V by Draper
Brackets evenly spaced along screen case
38 mm Typ
A
Series
E-small case 81 mm
E-large case 114 mm
54 mm
V
NOTE: Viewing surface shown is Series V with tab tensioning.
Series E, without tab tensioning, is also available.
Small Signature Case
Shown with
152
9.5mm
mm
threaded rod
(provided
by others).
248
cm
Electrical connection
to internal splice box
on left end of case. 22mm
232
knockout for 13mm
cm
conduit. J-Box cover located
under splice box.
Large Signature Case
Shown with
152
9.5mm
mm
threaded
rod (provided
by others).
280
cm
Electrical connection
to internal splice box
on left end of case. 22mm
232
knockout for 13mm
cm
conduit. J-Box cover located
under splice box.
SCREEN SIZE
Total Drop < 396 cm or viewing width < 366 cm
Total Drop > 396 cm or viewing width > 366 cm
See separate Serial Communication-RS232 Instruction sheet for
enabling RS232 with the MC1.
Program LED
Fuse
Eye Port for IR Eye. For RF Receiver or LED
MC1
Wall Switch, a Splitter and a Power Supply
is required. Plug RF Receiver or LED Wall
Switch and Power Supply into splitter, then
run cable from Splitter to MC1 Eye Port.
Case Dimensions and Methods of Installation
Case length
A
Viewing surface
Varies
Audience
Ceiling grid and tile
(by others)
Audience
Ceiling grid and tile
(by others)
CASE SIZE
Small
Large
MC1
Internal Screen Wiring
White or Blue-Common
Red-to Screen (directional)
Black-to Screen (directional)
Brown-Hot to AC
Green/Yellow-Ground
Low Voltage Wiring by others
AC Wiring by electrician
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
Manual Switch Up
Location of key
operated on-off
switch if furnished
To AC Line
www.draperinc.com
Tab-Tensioning Cable Adjustment
Draper's Tab-Tensioning System is factory-set, and
under normal circumstances will not require field
adjustment. If, however, you notice wrinkles, waves, or
other indications that the tensioning cables need to be
adjusted, follow the procedure below.
 Determine which side requires adjustment.
➁ Secure dowel with one hand.
Caution: Do not touch or bend surface.
➂ Using Phillips-head screwdriver, depress
spring-loaded adjustment screw (see
Ceiling grid
and tile
Fig. 1) and slowly turn clockwise to tighten
(by others)
tension, or counterclockwise to loosen tension.
The screw adjusts in ¼ turn increments. Adjust
only one increment (¼ turn).
➃ If problem is not corrected, leave screen in position
for 24 hours to allow surface material to stretch into position.
➄ If problem still is not corrected, repeat steps 2 and 3.
Single Station Control
CE Approved
Junction box at
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Green/Yellow (Motor Ground)
Control
switch
Dashed wiring
by installer
Low Voltage & Wireless Control
White/Blue (Common)
Red 110/Black 220 (Up)
Black 110/Brown 220 (Down)
Green 110V/
Green/Yellow 220V
(Motor Ground)
(765) 987-7999
Dowel
Wiring Diagrams
Multiple Station Control
Junction box at
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Green/Yellow (Motor Ground)
Red
Black
Red
Black
Red
Black
220v,
50 Hz.
220v, 50 Hz.
White or Blue-Common to screen & 110/220V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110/220V AC-Hot
Black-to 110/220V AC-Hot
Green/Yellow (Ground)
Dashed wiring by electrician
Low voltage wiring by others
Eye Port for IR Eye, RF Receiver or LED
Wall Switch. For more than one of
these, a splitter is required.
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Control
Aux Port for connecting additional LVC-III
Switches
modules (up to six total can be linked-
24v DC
connect from Aux to Eye).
Page 2 of 2
Tensioning
Cable
Adjustment
Screw
Figure 1
Not CE Approved
Cap off with wire
nut & tape
Blue
Blue
Blue
Dashed wiring
by installer
Internal Screen Wiring
White/Blue (Common)
Red 110/Black 220 (Up)
Black 110/Brown 220 (Down)
Green/Yellow
(Motor Ground)
To
110/220V
Line
STOP
Location of key
operated on-off
switch if furnished
STOP