Draper Signature E Series Installations- und Betriebsanleitung - Seite 2

Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Projektionsfläche Draper Signature E Series herunter. Draper Signature E Series 2 Seiten. Electric projection screen
Auch für Draper Signature E Series: Installations- und Betriebsanleitung (2 seiten), Installations- und Betriebsanleitung (2 seiten), Installations- und Betriebsanleitung (2 seiten)

Draper Signature E Series Installations- und Betriebsanleitung
Signature/Series E & V by Draper
Brackets evenly spaced along screen case
1
1
/
" Typ
2
A
Series
E-small case
E-large case
2
1
/
"
8
V
NOTE: Viewing surface shown is Series V with tab tensioning.
Series E, without tab tensioning, is also available.
Small Signature Case
Shown with
6"
3
/
" threaded
8
rod (provided
by others).
9¾"
Electrical connection
to internal splice box
7
on left end of case.
/
"
8
knockout for
1
/
" conduit.
9
1
/
"
2
8
J-Box cover located under
splice box.
Large Signature Case
Shown with
3
/
" threaded
8
6"
rod (provided
by others).
11"
Electrical connection
to internal splice box
on left end of case.
7
/
"
8
knockout for
1
/
" conduit.
9
1
/
"
2
8
J-Box cover located under
splice box.
SCREEN SIZE
Total Drop <156" or viewing width <144"
Total drop >156" or viewing width >144"
Two-Way Serial Communication (RS232) with MC1
See separate Serial Communication-RS232 Instruc-
tion sheet for enabling RS232 with the MC1.
Program LED
Fuse
MC1
Case Dimensions & Methods of Installation
Case length
A
3
/
"
3
Viewing surface
16
4
/
"
1
2
Varies
Audience
Ceiling grid and tile
(by others)
Audience
Ceiling grid and tile
(by others)
CASE SIZE
Small
Large
White-Common to screen & 110-120V AC Neutral
Red-to Screen (directional)
Brown-to Screen (directional)
Black-Hot to 110-120V AC
Green/Yellow-Ground
Low Voltage Wiring by others
AC Wiring by electrician
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
STOP
Manual Switch Up
Eye Port for IR Eye. For RF Receiver or LED
STOP
Wall Switch, a Splitter and a Power Supply
is required. Plug RF Receiver or LED Wall
Control
Switch and Power Supply into splitter, then
Switches
run cable from Splitter to MC1 Eye Port.
24v DC
www.draperinc.com
Tab-Tension Adjustment
Procedure for Signature/Series V
1 Determine which side requires adjustment.
2 Secure dowel with one hand.
Caution: Do not touch or bend surface.
3 Using Phillips-head screwdriver, depress
spring-loaded adjustment screw
(see drawing) and slowly turn
clockwise to tighten tension, or
counterclockwise to loosen tension.
Ceiling grid
The screw adjusts in ¼ turn increments.
and tile
Adjust only one increment (¼ turn).
(by others)
4 If problem is not corrected, leave screen in
position for 24 hours to allow surface
material to stretch into position.
5 If problem still is not corrected, repeat steps 2 and 3.
Please Note: Do not wire motors in parallel.
Single Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green/Yellow (Ground)
Dashed wiring
by electrician
Control
Single gang box by others
switch
1
Min. 4" x 2
/
Blue
Red
Black
Location of key
operated on-off
switch if furnished
To 110-120V Line
Low Voltage & Wireless Control
Caution: Do not remove the roller assembly from the case unless
Internal Screen Wiring
necessary for repairs. If the roller assembly is removed, be sure mo-
White (Common)
Red (Up)
tor is fully re-seated in the bracket, and re-secure it carefully with the
Black (Down)
Green/Yellow (Gnd)
motor retaining spring and screw (see diagram below).
To
110-120V
Line
Location of key
operated on-off
switch if furnished
(765) 987-7999
Dowel
Wiring Diagrams
Multiple Station Control
Red
7
" x 1
/
" deep
8
8
Black
Red
Black
Red
Black
Location of key
operated on-off
switch if furnished
To 110-120V Line
White-Common to screen & 110-120V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110-120V AC-Hot
Black-to 110-120V AC-Hot
Green-Ground
Dashed wiring by electrician
Low voltage wiring by others
Eye Port for IR Eye, RF Receiver or LED
Wall Switch. For more than one of
these, a splitter is required.
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Aux Port for connecting additional LVC-III
modules (up to six total can be linked-
connect from Aux to Eye).
Please note: Maximum
torque for tightening
screw is 5 lb-inches.
Page 2 of 2
Tensioning
Cable
Adjustment
Screw
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green/Yellow (Ground)
Cap off with wire
nut and tape
Blue
Dashed wiring
by electrician
Blue
Blue
Single gang box by others
Min. 4" x 2
1
/
" x 1
7
/
" deep.
8
8
3 shown. More or less equally
feasible.
Internal Screen Wiring
White (Common)
Red (Up)
Black (Down)
Green (Ground)
To
110-120V
Line
STOP
Location of key
operated on-off
switch if furnished
STOP
Control
Switches
24v DC