CONNECTING YOUR MACHINE TO THE POWER SUPPLY: (240V)
To eliminate the possibility of an electric shock your machine has been fitted with a BS
approved, non rewireable moulded plug and cable which incorporates a fuse, the value
of which is indicated on the pin face of the plug. Should the fuse need to be replaced an
approved BS1362 fuse must be used of the same rating, marked thus
The fuse cover is detachable, never use the plug with the cover omitted. If a replacement
fuse cover is required, ensure it is of the same colour as that visible on the pin face of the
plug (i.e. red). Fuse covers are available from your Draper Tools stockist.
If the fitted plug is not suitable, it should be cut off and destroyed. *The end of the cable
should now be suitably prepared and the correct type of plug fitted. See below.
*WARNING:
A plug with bare flexible wires exposed is hazardous if engaged in a live power socket
outlet.
WARNING: THIS APPLIANCE IS DOUBLE INSULATED.
Blue – Neutral, Brown – Live.
As these colours may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured blue must be connected to the terminal which is marked with
the letter 'N' or coloured black or blue.
The wire which is coloured brown must be connected to the terminal which is marked
with the letter 'L' or coloured red or brown.
CONNECTING YOUR MACHINE TO THE POWER SUPPLY (110V)
To eliminate the possibility of an electric shock your machine has been fitted with a BS
approved, rewireable plug and cable. If the fitted plug is not suitable, it should be
removed, the end of the cable should be suitably prepared and the correct type of plug
fitted. See below.
WARNING: THIS APPLIANCE IS DOUBLE INSULATED.
Single phase 110 volt machines must be connected using the relevant coding and
matching the colour of the flexible cable to that of the plug. The procedure is as follows:
1. Connect brown coloured core to plug terminal marked letter 'L' (live).
2. Connect blue colour core to plug terminal marked letter 'N' (neutral).
Ampere rating
(on Name plate)
Extension cable length
7.5m
15m
22.5m
30m
45m

POWER SUPPLY

3
0.75
0.75
0.75
0.75
0.75
6
Wire Size mm
0.75
0.75
0.75
0.75
1.25
- 5 -
10
13
2
1.0
1.25
1.0
1.5
1.0
1.5
1.25
1.5
1.5
2.5
.