Draper LightBloc Zip Installationsanleitung Handbuch - Seite 3

Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Inneneinrichtung Draper LightBloc Zip herunter. Draper LightBloc Zip 6 Seiten.
Auch für Draper LightBloc Zip: Installationsanleitung Handbuch (6 seiten)

Draper LightBloc Zip Installationsanleitung Handbuch
LightBloc
Mounting Headbox - Zip 127 Angled Headbox
The LightBloc Zip 127 Angled Headbox can be mounted permanently to the
wall or ceiling (See Mounting Headbox - Permanently to Ceiling or Wall on
page 1); or the Headbox can rest atop the Side Channels and is held in place
there by two mounting studs coming down from the endcaps.
PLEASE NOTE:
Steps 1-5 of the Mounting Side Channels
section must be completed before mounting
the Zip 127 Angled Headbox. It is critical that
the full length of each Side Channel
is secured to the mounting surface.
1 Remove screws from bottom of Headbox,
remove Fascia and set aside. (See Fig. 11).
HEADBOX
MOUNTING
STUD
S i
d e
C h
a n
n e
l
3 Insert "Zippers" on the side of the Hem Bar into the fabric retainers in the
Side Channels (See Fig. 12).
4 Insert Headbox mounting stud into Side Channel (See Fig. 12).
5 Return Fabric Retainers to Side Channels and re-attach Covers.
The LightBloc Zip can also be installed in a pocket in the ceiling. You must
provide adequate clearance for removal of the Roller Assembly during
installation and maintenance.
The minimum depth of the ceiling pocket for the LightBloc Zip 92 is 4¾"
(120mm), and for the LightBloc Zip 127 is 6¼" (158mm). See Fig 13 below.
FlexShade Zip 92
4 ¾"
(120mm)
3
/
"
5
(92mm)
8
7¼"
(
183mm)
Figure (11)
Zip by Draper
2 Insert "Zipper" on one side of
the Hem Bar into the fabric
retainer in the Side Channels
(See Fig. 12).
HEADBOX
MOUNTING
STUD
S i
d e
C h
a n
n e
Figure (12)
l
Pocket Installation
FlexShade Zip 127
6¼" (
5" (
3
5
/
"
8
(92mm)
5
7
/
"
8
(148mm)
If the system is installed in a recess, it is unlikely that there will be sufficient
space above the side channels to allow the Headbox to be mounted onto them.
In these instances follow the steps for preparing the system (See Mount-
ing Headbox - Zip 127 Angled Headbox). Then mount the Headbox onto
the side channels and present the entire system into the opening. Hold the
Figure (11)
system in position and use appropriate screws to fix the side channels in
place. Apart from this, the other steps should be followed as described.
The LightBloc Zip operates on 110-120V, 60 Hz. current. Shade is shipped
with internal wiring complete and control switch (es) fully boxed, and supplied
with a 6' cable lead (standard). Longer lead can be substituted by removing
REMOVE
two screws in motor end of roller, removing lead, plugging new lead in, and
FASCIA
replacing screws. Wire to connect shade to switch (es) and switch (es) to
power supply should be furnished by installer. Connections should be made
in accordance with attached wiring diagram, and wiring should comply with
national and local electrical codes.
DO NOT wire motors in parallel without written permission from Draper.
All operating switches should be "off" before power is connected.
ZIPPER
CAUTION: Be sure all switches are in "off" position before adjusting limit switches.
Always be prepared to shut off manually when new adjustment is being tested.
Do not allow the shade roller to become exposed by running the shade
fabric too far down. Shade may be severely damaged if allowed to run too far up
or down. Each shade's limit switch must be set if using group control system.
HEMBAR
1 Fully depress both limit switch push buttons, then operate wall switch to make
sure system works properly.
2 Raise shade to desired "up" stop position.
3 Set upper limit by depressing and releasing the proper (back) push button.
FABRIC
4 Lower shade to desired "down" stop position.
RETAINER
5 Set lower limit by depressing and releasing the proper (front) push button.
STRIP
For instructions on setting limits on these motors, consult Draper's Motorized
Shade Handbook, available in the motorized shades section of www.draperinc.com.
1 Connect the ILT switch to the motor via the terminal blocks, or via the modular
port using four conductor modular cable. When using modular cable, the cable
connectors MUST NOT be crimped in
reverse, as with standard telephone cable.
2 Set the slide switch to the lower
position. Press and hold the DOWN
button on the switch to move the
viewing surface to the desired lower
limit. If the shade moves in the opposite
direction, release the DOWN button
and press and hold down the STOP
button for four seconds. This will
reverse the operation of the
UP and DOWN switches.
3 Move slider switch into center position.
Wait a couple of seconds.
158mm)
Please Note: If you move the slider switch
from down to up in one motion it sets the two
127mm)
limits in the same position.
4 Set the slide switch to the higher
5"
position. Move the shade to the desired
(
127mm)
upper limit by pressing and holding the
UP button on the wall switch.
7¼"
(
183mm)
5 Return the slide switch to the center
position to return to normal operation.
6 To set the shade to an intermediate
position, move the shade to the desired
position and press the STOP button. Press and hold the STOP button for at
least three seconds to record the postion.
Please Note: Pressing and releasing the UP button on the switch will move the shade to its
Figure
upper limit. Pressing and releasing the DOWN button will move the shade to its lower limit.
While the motor is in motion, pressing the STOP button for less than two seconds will stop the
shade at its present position. Once the motor is stopped, pressing the STOP button will move
the shade to its intermediate position.
Pressing and holding the STOP button, when the motor is at rest or in motion, for at least
three seconds will record a new position.
www.draperinc.com
(765) 987-7999
Alternate Mounting for Jamb Recessed
Installations (Zip 127 Angled Only)
Complete Electrical Connection
Limit Switch Adjustments—Standard Motor
Limit Switch Adjustments—RTS Motors
Limit Adjustments (ILT Motors)
FlexShade Zip 92
4 ¾"
(120mm)
3
/
"
5
(92mm)
8
3
5
/
"
8
(92mm)
5
7
/
"
8
(148mm)
Page 3 of 6
POSITION
FUNCTION
POSITION
FUNCTION
Set LOWER limit
DOWN
Set LOWER limit
DOWN
Set UPPER limit
UP
Set UPPER limit
UP
Normal Operation
CENTER
Normal Operation
CENTER
Back View of Wall Switch
Back View of Wall Switch
To Motor
To Motor
with
with
Built-In
Built-In
Low Voltage
Low Voltage
Slide
Switch
Slide
C
Switch
o
D
m
+
o
m
U
C
5V
w
o
To Motor
p
DC
n
o
n
with
D
m
+
Built-In
o
m
U
Low Voltage
5V
w
o
To Motor
p
DC
n
n
with
Built-In
Low Voltage
Please Note: 5V DC must be
connected to be able to set