Section 8 - Limit Setting: RTS Obstacle Detection Motors

Programming Instructions
1. Connect power to one motor. Select a transmitter channel to assign motor. Hold UP and DOWN buttons until motor jogs, then
release.
2. Check motor direction. To reverse motor direction, hold MY/STOP button for 5 seconds until motor jogs. Check direction again.
Please note: Failure to complete Step 2 before Step 3 can only be corrected with a motor reset
3. Move motor to upper limit position. Hold MY/STOP and DOWN buttons until motor moves down, then release.
Use UP and DOWN buttons to move shade to correct lower limit and press MY/STOP.
4. While motor is at lower limit, hold UP and MY/STOP buttons until motor moves up, then release. The shade should move to
upper limit and stop.
5. Next, hold MY/STOP button for five seconds until motor jogs.
6. Put motor into USER MODE by pressing small programming button
7. Disconnect power to this motor and move to next motor in installation and start with Step 1.
8. Reconnect motor to power when all motors are programmed.
ADVANCED PROGRAMMING:
Setting an Intermediate Stop - Shade MUST BE in USER mode.
1. Move shade to desired mid-point location and hold MY/STOP button until motor jogs.
2. To test, press the MY/STOP button when motor is standing still. The shade will move
to that intermediate location.
3. To delete an intermediate stop, go to the intermediate stop and hold the MY/STOP
button until motor jogs.
ADVANCED PROGRAMMING: Add a Channel - Shade MUST BE in USER mode.
1. Select channel currently operating motor, then hold programming button until motor jogs.
2. Select new channel to add to motor, then hold programming button until motor jogs.
3. The motor should now work on both the old and new channel.
ADVANCED PROGRAMMING: Delete a Channel - Shade MUST BE in USER mode.
1. Select channel operating motor that you want to keep, then hold programming button until motor jogs.
2. Select channel to remove, then hold programming button until motor jogs. Motor should now only work on channel kept from Step 1.
ADVANCED PROGRAMMING: Adjust Limits in USER Mode
1. Move motor to limit
(upper or lower)
2. Hold UP and DOWN buttons until motor jogs.
3. Move motor to its new limit location and hold MY/STOP button until motor jogs.
ADVANCED PROGRAMMING: Reset Motor
1. Disconnect power for 5 seconds and reconnect to power for 15 seconds. Disconnect power for 5 seconds, then reconnect to power
and leave connected. Shade should roll down a few inches and stop.
2. Hold programming button
now reset and ready to be programmed.
ADVANCED PROGRAMMING: Adjusting Obstacle Detection Sensitivity
SHADE
This function gives the possibility to adjust the obstacle detection during the downward movement to deactivate it or adjust the sensitivity.
1. Starting with shade at the half-way position, press MY and UP briefly and again MY and UP for 2 seconds. The shade jogs.
my
my
2. Within 10 seconds press UP or DOWN to change the level of detection.
2 SEC.
my
SHADE
3.
my
2 SEC.
to be changed. Shade must move to previously set limit and will stop automatically.
for 15 seconds. Motor will jog up and down once; pause and then jog a second time. Motor is
(see Figure 9)
Without feedback within 10 seconds the actuator goes back to USER MODE. Go back to Step 1.
ESD level 0:
SHADE
The obstacle detection
is more sensitive.
The shade moves up
and down slowly.
SLOW JOG
Press MY for 2 seconds to validate the setting.
The shade jogs.
(see below)
on the back of transmitter until motor jogs.
(Fig. 9)
ESD level 1:
SHADE
- Obstacle
(DEFAULT)
detection is reliable
my
on most zip shades.
The shade jogs.
SHORT JOG
page 7 of 12
.
Figure 9
Programming
Button
ESD level 2:
SHADE
Obstacle detection
is deactivated.
my
The shade moves up
and down slowly.
SHORT JOG
UP
STOP
DOWN
LED Lights
Channel
Selector
Pen
BACK