Draper Skylight FlexShades Einbauanleitung - Seite 3

Blättern Sie online oder laden Sie pdf Einbauanleitung für Inneneinrichtung Draper Skylight FlexShades herunter. Draper Skylight FlexShades 4 Seiten.

Draper Skylight FlexShades Einbauanleitung
Skylight FlexShades by DRAPER
Roller Assembly/Installation
Re-install motor/roller assembly by generally reversing the steps in the
"Installation Preparation" section.
Re-install the spring roller by generally reversing the steps in the
"Installation Preparation" section. Note that the notch on the spring roller
must be positioned to face out, toward the frame, not in toward the motor
end headbox (see Fig. 11).
Notch faces away
from motorized end
Wedge something soft, such as Styrofoam, between the spring roller and
its headbox to keep the spring roller from moving.
®
Feed Kevlar
ribbon down through the side channels to the take-up reels
on the motor roller assembly, using the ribbon feed tool provided (see
Fig. 12). Make sure ribbon does not twist: a twisted ribbon will cause
shade to lock up.
Ribbon
Ribbon
feed tool
Note: Be careful when starting the slat bar and fabric into the side channels to
avoid tearing the fabric. Use a screwdriver or the ribbon feed tool to work the
ribbon under the pulley.
Remove the screw (with washer) in each pulley and re-install through hole
®
in Kevlar
ribbon (see Fig. 13). Be careful not to "strip" the screw hole.
Remove wedge from spring roller.
Slat Bar
Extender
1
4-40 x
/
"
4
screw on
window side
Slat Bar
Figure 11
Figure 12
Self-tapping screw
Spring washers
Roller
R
Kevlar ribbon
Punch holes for
screw - do not
try to drill.
Figure 13

Electrical Connections

Shade operates on 115 V., 60 Hz. current.
Shade is shipped with internal wiring complete and control switch(es) fully
boxed. Shades plug into junction box located inside headbox. Wiring to
controls and electrical must then be completed from the junction box box.
Connections should be made in accordance with attached wiring diagram, and
wiring should comply with national and local electrical codes.
All operating switches should be "off" before power is connected.
Adjustments
Adjust limit switches so the fabric can be completely drawn or retracted
without the slat bar leading edge going beyond the fabric retention guides
located at the upper end of each side channel. Limit switches are set by
the installer.
A. Fully depress both limit switch push buttons, then operate switch to
make sure system works properly.
B. Raise shade to desired "up" stop position.
C. Set upper limit by depressing and releasing the proper push button
(see Fig. 15).
Figure 15
D. Lower shade to desired "down" stop position.
E. Set lower limit by depressing and releasing the proper push button.
NOTE: Limit switches can be set with a single motor switch on a test cord
furnished by Draper, Inc. upon request. For multiple unit installations, each
shade's limit switch must be set before hooking them up to a group control
system.
Once adjustments have been completed, re-install headbox covers.
Single Shade Wiring Diagram
For multiple shades or low voltage wiring, consult diagrams provided
with control.
Control
switch
Brown
Red
To 115V Line
NOTE: This wiring diagram is for standard right-hand motor placement,
fabric from rear of roller. It also applies for left-hand motor placement,
fabric from the front of the roller. For left hand motor placement with
fabric from rear of roller, or right hand motor placement with fabric from
front of roller, Red becomes "Up" and Black becomes "Down."
Page 3 of 4
Push
Buttons
Internal Shade Wiring
White (Common)
Black (Up)
Red (Down)
Green (Ground)
Single gang box by others
1
7
Min. 4" x 2
/
" x 1
/
" deep
8
8
Black
Dashed wiring by electrician