AirStage AUXB24L Betriebshandbuch - Seite 9

Blättern Sie online oder laden Sie pdf Betriebshandbuch für Klimagerät AirStage AUXB24L herunter. AirStage AUXB24L 9 Seiten. Vrf system indoor unit cassette type

The following conditions may not be breakdowns so check again.
Symptom
Doesn't operate at all:
The operation mode
cannot be changed:
Poor Cooling
(or Heating)
performance:
Set the temperature lower
than the room tempera-
ture and use it:
In the following situations stop operation immediately and get in touch with authorized
service personnel.
● The problem cannot be solved even when the troubleshooting checks have been performed.
● The OPERATION indicator lamp (green) is flashing very fast.
● The wired remote controller or simple remote controller indicate Er (when connected).
● It has burning smell.

SPECIFICATIONS

MODEL
POWER SOURCE
AVAILABLE VOLTAGE RANGE
COOLING CAPACITY
HEATING CAPACITY
SOUND PRESSURE LEVEL
HIGH
MED
LOW
DIMENSIONS & WEIGHT
HEIGHT
WIDTH
DEPTH
WEIGHT
MODEL
POWER SOURCE
AVAILABLE VOLTAGE RANGE
COOLING CAPACITY
HEATING CAPACITY
SOUND PRESSURE LEVEL
HIGH
MED
LOW
DIMENSIONS & WEIGHT
HEIGHT
WIDTH
DEPTH
WEIGHT
Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor
● Has there been a power failure?
● Has a fuse blown out, or a circuit breaker been tripped?
● Is the main power switch set to the OFF position?
● Are you trying to engage in an operation different from the priority state?
● Is it in standby state?
● Are you trying to change to an operation different from the priority conditions?
● Did you adjust the room temperature settings (thermostat) correctly?
● Is the air filter dirty?
● Are the air conditioner's inlet port or outlet port blocked?
● Is there a window or door open?
● In the case of Cooling operation, is a window allowing bright sunlight to enter?
(Close the curtains.)
● In the case of Cooling operation, are there heating apparatus and computers
inside the room, or are there too many people in the room?
● Is the fan speed set to low?
● Temperature does not fall down well.
Temperature may not fall down depending on the room conditions.
(While high humidity or the room temperature is high.)
AUXB07L
[kW]
2.20
[kW]
2.80
dB [A]
34
dB [A]
30
dB [A]
25
[mm]
[mm]
[mm]
[kg]
AUXD18L
AUXD24L
[kW]
5.60
[kW]
6.30
dB [A]
36
dB [A]
30
dB [A]
29
[mm]
246
[mm]
840
[mm]
840
[kg]
23
unit.
According to IEC 704-1 and ISO 3744.
Items to check
AUXB09L
AUXB12L
230 V~50 Hz
198 to 264 V
2.80
3.60
3.20
4.10
35
37
30
34
25
27
245
570
570
15
AUXA30L
230 V~50 Hz
198 to 264 V
7.10
9.00
8.00
10.0
38
40
33
38
29
33
AUXB14L
AUXB18L
4.50
5.60
5.00
6.30
38
41
34
35
27
27
245
570
570
17
AUXA36L
AUXA45L
11.2
12.5
12.5
14.0
44
46
38
39
33
33
288
840
840
27
See page
4
4
4
5
4
AUXB24L
7.10
8.00
50
44
30
AUXA54L
14.0
16.0
47
39
33
En-8