Bosch Benchmark Series Service-Handbuch - Seite 32
Blättern Sie online oder laden Sie pdf Service-Handbuch für Backofen Bosch Benchmark Series herunter. Bosch Benchmark Series 36 Seiten. Built-in wall ovens
Auch für Bosch Benchmark Series: Installationshandbuch (32 seiten), Kurzreferenz-Handbuch (4 seiten), Service-Handbuch (45 seiten), Installationsanleitung Handbuch (40 seiten), Schnellstart- und Sicherheitshandbuch (13 seiten)
58300000187895 ARA EN A
Error
Description
Code
E106
Door latch does not lock
E107
Door latch does not unlock
E115
Unlocked cavity temperature too
high
E116
Meat probe error
Copyright by BSH Home Appliances Corporation
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
MAY 2015
Cause/Notes
Latch operation not determined by control
module. Door latch does not lock after 1
minute and further attempts will stop. Error
will be cancelled and normal operation
resumed if a locked door is no longer required.
See Cavity 1 (upper) Small Load Schematic.
Temperature in cavity is too high or latch
operation not as expected. Door latch does not
unlock after 1 minute and further attempts will
stop. If the latch is detected in open state for
more than 10 seconds, the error will clear and
normal operation will resume. See Cavity 1
(upper) Small Load Schematic.
Temperature in unlocked cavity exceeds the
allowable temperature. Oven will stop heating
and door will lock. When temperature reaches
allowable range, door latch unlocks, error is
cleared, and oven will resume heating.
"Hot" wire shorted to ground. Connection to
the probe changes from connected-to-
disconnected multiple times. Probe is disabled,
but oven continues to operate. Error will be
cleared and probe enabled after a control
reset. Standard probe assembly is part of the
control module; see Communication
Schematic.
1901 Main St ▪ Suite 600 ▪ Irvine, CA 92614
Service Manual for Bosch Benchmark Series Induction Slide-in Ranges
Suggested Action(s)
Check latch motor and switch
connections/wires.
Check connections to control board.
Check wires between control board and
latch. Check operation of door switch.
Check latch for binding/mechanical latch
failure.
Check latch motor and switch operation.
Check door switch operation.
Check latch for binding/mechanical latch
failure.
Check for stuck relays.
Check element operation.
Check temperature sensor resistance;
replace sensor if necessary.
Check wires and connections; connector
may be loose and shorted to cavity or other
dead metal.
Check for dirty contact within probe
receptacle.
Page 32 of 36
800 944-2904