Alemlube 51037M Technisches Handbuch für den Eigentümer
Blättern Sie online oder laden Sie pdf Technisches Handbuch für den Eigentümer für Schmierungssysteme Alemlube 51037M herunter. Alemlube 51037M 7 Seiten. Auto shut off nozzle with digital meter
Description
The 51037M auto shut off nozzle uniquely designed with a built in digital meter is suitable for dispensing diesel fuel,
petrol, kerosene and will automatically shut off when a tank is full. This innovative combination of nozzle and meter saves
simplifies traditional separate nozzle and meter thinking and saves installation and usage time.
The digital meter is powered by 2 x AAA batteries, displays a 5-digit resettable total and a 7-digit (non resettable)
cumulative total function, and is accurate to ±1%. The LCD display can indicate several modes by pressing the menu
button including level of battery charge, flow rate, calibration and units of dispensed fuel (litres, gallons, pints or quarts).
And for peace of mind, spare parts for both nozzle and meter are readily available.
Flow rates of up to 60 L/min are achievable within operating temperatures of -10ºC to 60ºC with an operating pressure of
7 to 50psi (0.5-3.5 bar).
The 51037M comes complete with a 1" BSP(f) swivel and the outlet spout is 19mm (3/4") in diameter.
Specifications
Flow rate:
Operating pressure (Max): 50psi (3.5bar)
Operating temperature:
Accuracy:
Fluid type:
Digital Screen:
Inlet and Outlet:
Weight:
Power supply:
INTRODUCTION:
Technical Data
1.1
1.1.1 The liquids compatible with auto shut off digital nozzle must be low viscosity.
LCD Display
1.2
The "LCD" of the meter features two numerical Registers and various indications
displayed to the user only when the applicable function so requires
KEY
�ndication of resetting present total to �ero
1. Partial register (5 figures with moving comma from 0.1 to 99999)
Total register
Indicating the volume dispensed since the reset button was last pressed
�ndication of flow rate mode
2. Indication of battery charge
�ndication of unit of measurement of partial: L= Litres
3. Indication of calibration mode
4. Indication of resetting present total to Zero
5. Total register
6. Indication of flow rate mode
7. Indication of unit of measurement of partial: L= Litres
NSW
1.3 USER BUTTONS
TEL: (02) 9939 0711
FAX: (02) 9939 0411
The turbine digital meter features two buttons (MENU and RESET) which individually perform two main
Visit our website at
functions and together, other secondary functions.
OWNER'S TECHNICAL MANUAL
51037M
Auto Shut Off Nozzle with Digital Meter
Up to 60L/min
-10 º C ~ 60ºC
±1%
Diesel, petrol & kerosene
5-Digit present total (0.01~999.99)
7-Digit non-resettable total (1~9999999)
Units - Litres, gallons, pints, quarts
1" BSP swivel inlet & 19mm (3/4") outlet spout
1.3kg
2 x AAA
QLD/PNG
VIC/TAS
TEL: (07) 3204 9166
TEL: (03) 8787 8288
FAX: (07) 3204 1224
FAX: (03) 8787 8266
www.alemlube.com.au
GAL = Gallons
PT = Pints
QT = Quarts
WA
TEL: (08) 9302 4199
FAX: (08) 9303 2095
Email - [email protected]
51037M
Fig. 1
SA/NT
NZ
TEL: (08) 8241 7111
TEL: (09) 447 1007
FAX: (08) 8241 7011
FAX: (09) 447 1008