It is necessary to observe the below requirements during the electric wiring.
The wiring diagram is also attached to the heater on the side of the electrical installation
guard (Figure 8).
The electrical installation may only be connected, repaired and inspected by a person
authorised to perform that activity.
Expert connection must be confirmed on the warranty certificate, or demonstrated
by another certificate.
The heater is connected to the 3x 230 V/50 Hz power grid using a fixed moving conductor
with a switch that turns off all the grid poles and the circuit breaker (protector).
Cable 5 x 2.5 mm2, supply protection 3 x 16 A/B
Installations in bathrooms, laundry rooms, washrooms and showers must be in compliance
with the standard.
The degree of protection of electric parts of the heater is IP 44.
Adhere to the protection against electric shock injury according to standard.
Wiring scheme
R1 , R2 , R3 - rating element- 230 VAC, 2200 W, 9.5 A
1 - blue control lamp - 2.2 kW
2 - red control lamp - fast heating 6.6 kW
ST - power relay, inductor 230 VAC
Re - power relay, inductor 230 VAC
Fu - fuse Ø 5mm x 20mm, 500 mA
TL - button- fast heating, START
Te1 - service thermostat - round control button on the control knob
Te2 - thermostat and thermal (emergency) fuse
- inside the control, under the electrical installation cover
PE, N, L1, L2, L3 - connecting terminals, power supply
HDO - external contact terminal
- locking / switching with HDO tariff switch
(contact switches current 9.5 A)
FVE -external contact terminal - preferred fast heating
(contact switches current to 0.5 A)
TL -external push button terminal
Figure 8
- 12 -