of X0 ± n mm or Z0 ± n mm (see
Technical Data), if the XY plane in
which lies the CLS.. is parallel to
the XY plane in which lies the
sensor.
3.2
Cylindrical sensors
The alignment between SMS..
and CLS.. must be carried out:
• radially, centering sensor and
magnetic unit so that the axes
of the two cylindrical cases
match (see A Axis in Figure 5),
• angularly, facing the
Fig. 5: Cylindrical sensors alignment and operation
6
corresponding sensor and
magnetic unit arrow lines, so
that the printed lines B and C
are parallel (see Figure 5).
The operation must be carried out
by bringing the magnetic unit
closer to the sensor axially or
radially. The SMS../CLS.. axes
must coincide for axial operating
movement or must be parallel for
radial operating movement.
The SMS.. sensors can be
properly operated also when the