Bosch 1530 Betriebs-/Sicherheitshandbuch - Seite 10
Blättern Sie online oder laden Sie pdf Betriebs-/Sicherheitshandbuch für Elektrowerkzeug Bosch 1530 herunter. Bosch 1530 33 Seiten. Nibbler
Auch für Bosch 1530: Betriebs-/Sicherheitshandbuch (28 seiten)
BM 1609929Y03 06-10:BM 1609929Y03 06-10 6/14/10 9:33 AM Page 10
Preventive maintenance
W RNING
performed by unauthorized
personnel may result in misplacing of
internal wires and components which
could
cause
recommend that all tool service be
performed by a Bosch Factory Service
Center or Authorized Bosch Service Station.
TOOL LUbRICATION
Your Bosch tool has been properly lubricated
and is ready to use. It is recommended that
tools with gears be regreased with a special
gear lubricant at every brush change.
CARbON bRUSHES
The brushes and commutator in your tool
have been engineered for many hours of
dependable service. To maintain peak
efficiency of the motor, we recommend every
two to six months the brushes be examined.
Only genuine Bosch replacement brushes
specially designed for your tool should be
used.
bEARINGS
After about 300-400 hours of operation, or at
every second brush change, the bearings
If an extension cord is
W RNING
necessary, a cord with
adequate size conductors that is capable of
carrying the current necessary for your tool
must be used. This will prevent excessive
voltage drop, loss of power or overheating.
Grounded tools must use 3-wire extension
cords that have 3-prong plugs and receptacles.
NOTE: The smaller the gauge number, the heavi-
er the cord.
* Punch
* 3- position die
** Swivel die
** Carrying case
Maintenance
Service
serious
hazard.
Extension Cords
Accessories
2 608 639 013
2 608 639 904
2 608 639 901
should be replaced at Bosch Factory Service
Center or Authorized Bosch Service Station.
Bearings which become noisy (due to heavy
load or very abrasive material cutting) should
be replaced at once to avoid overheating or
motor failure.
We
W RNING
the power supply before cleaning or
performing any maintenance. The tool may
be cleaned most effectively with compressed
dry air. Always wear safety goggles when
cleaning tools with compressed air.
Ventilation openings and switch levers must
be kept clean and free of foreign matter. Do
not attempt to clean by inserting pointed
objects through openings.
C UTION
plastic parts. Some of these are: gasoline,
carbon tetrachloride, chlorinated cleaning
solvents, ammonia and household detergents
that contain ammonia.
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Cord Size in A.W.G.
Tool's
Ampere
Cord Length in Feet
Rating
25
3-6
18
6-8
18
8-10
18
10-12
16
12-16
14
(*= standard equipment)
(**= optional accessories)
-10-
Cleaning
To avoid accidents always
disconnect the tool from
Certain cleaning agents
and
solvents
damage
Wire Sizes in mm
Cord Length in Meters
50
100 150
15
30
60
16
16
14
0.75 0.75 1.5
16
14
12
0.75 1.0 2.5
16
14
12
0.75 1.0 2.5
16
14
12
1.0 2.5 4.0
12
—
—
—
—
—
2
120
2.5
4.0
4.0
—
—