OPERATING INSTRUCTIONS

Refer to "Conditions for Testing" before conducting a Standard or Passive test.
On/Off
Press and hold the power button for 1-2 seconds to switch the device on or off.
Taking a standard test
1. Attach a mouthpiece onto the sample port and select the Standard Test icon.
2. The breathalyser will take a Blank Test to ensure the mouthpiece and sensor are clear of alcohol
from previous tests.
3. If the Blank Test result shows 0.000, the unit will proceed to test mode (skip to step 5).
4. If alcohol is detected, verify that a clean mouthpiece is being used and select retest.
5. Use the stylus pen to input information.
6. When the screen displays "Please Blow", take a deep breath and blow into the mouthpiece with
a slow and steady breath until the BEEP tone stops and the Time and Volume bars are full.
• A photo will be taken while the subject is blowing.
• A passive test can be taken by pressing the
7. The test result will display on the screen. Press
8. If the subject did not blow within 30 seconds, the administrator can press
the subject refused to take a test, or press
or
to exit.
9. If the subject failed to give a valid breath sample, the administrator can press
to allow the subject to take the test again.
10. Select
to print the test result.
11. Push the button underneath the mouthpiece to remove the mouthpiece and take another test.
Taking a passive test
1. Attach a sampling cup onto the sample port and select the Passive Test icon.
2. When the screen displays "Please Blow", take a deep breath and blow into the sampling cup
until the BEEP tone stops.
3. Press
to take a manual sample while the subject is still blowing into the sampling cup.
4. An "Alcohol Detected" or "No Alcohol" result will display on the screen.
5. The next test can be taken immediately after a "No Alcohol" result.
6. If "Alcohol Detected" result was displayed, use a mouthpiece to perform a Standard Test to
confirm the test result.
icon while the subject is still blowing.
to go to the next screen (review results).
to allow the subject to take a test again,
to confirm that
to confirm or