ATI Technologies SR-82 Ersatz-Handbuch - Seite 4

Blättern Sie online oder laden Sie pdf Ersatz-Handbuch für Zubehör ATI Technologies SR-82 herunter. ATI Technologies SR-82 10 Seiten. Robotic collision sensor switch

Manual, Collision Sensor Switch Replacement, SR‑82
Document #9610‑60‑1017‑03

1.3 Safety Precautions

WARNING: Do not perform maintenance or repair on the Collision Sensor with air
pressure applied, current supplied to the sensor, or the robot not in a safe condition.
Injury or equipment damage can occur if this is not observed. Always ensure that air
pressure has been vented from the unit, that electrical current is not supplied to the
Collision Sensor's signal circuit, and that the robot is in a safe, locked‑out condition
consistent with local and national safety standards before performing maintenance or
repair on the Collision Sensor.
WARNING: The Collision Sensor is only to be used for intended applications and
applications approved by the manufacturer. Using the Collision Sensor in applications
other than intended will result in damage to Collision Sensor or end‑of‑arm tooling and
could cause injury to personnel.
CAUTION: Do not adjust or remove either of the (2) set screws installed in the wall of
the body. Doing so may result in damage to the unit or failure of the switch to operate.
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 USA • Tel: 919.772.0115 • Fax: 919.772.8259 • www.ati‑ia.com
4