SETTING THE DESIRED HUMIDITY LEVEL
The control will allow you to set
the desired humidity level in your
space and can be used to turn
dehumidification on or off.
Begin by pressing the ON button
and ON will be displayed on the
LCD Screen (see LCD display in
FIGURE 1). Use the arrow buttons
to set the control to the desired
humidity level.
Raise the setting if you prefer
the air to be less dry; this will
reduce the amount of time that
the dehumidifier runs.
Lower the setting if you prefer
the air to be more dry; this will
increase the amount of time
that the dehumidifier runs.
LCD DISPLAY
FIGURE 2 – LCD DISPLAY
Numbers show
current room humidity
OR humidity setting
Solid ON:
Control On
Blinking ON:
Dehumidifying
OFF: Control Off
90-1636
FIGURE 1 – CONTROL DISPLAY AND USER BUTTONS
LCD
Mode Buttons
Display
Use to turn
Use to view and set
control On/Off.
humidity or dryness
level setting.
SET is displayed
when
pressed. The value
displayed is the
humidity setting.
See FIGURE 6.
*
Blinking ON +
: Control Limit Exceeded.
See CONTROL LIMITS, page 7.
TURNING CONTROL ON/OFF
• Pressing the ON button will turn on the control.
• Pressing the OFF button will turn off the control.
• The control will continue to display the measured
humidity when OFF.
• The humidity or dryness level setting cannot be
changed when the control is OFF.
CHANGING THE HUMIDITY SETTING
• The first press of either the
display the humidity or dryness level setting on the LCD.
• Each subsequent push of the up or down buttons
will change the setting by 1% RH.
Buttons
• If a button is held down, the setting will continually
change by 1% every 1/2 second for as long as the
button is pressed.
• The control will exit the setting screen 5 seconds
after the last button press/release.
HOW DOES THE CONTROL WORK?
• When the measured humidity is greater than the
setting, the control will turn on the dehumidifier and
ON will blink on the LCD display.
• When the measured humidity falls 3% below the
setting, the control will turn off the dehumidifier and
or
is
ON will stop blinking.
CONTROL LIMITS
The control limits are used to make sure the dehumidifier does not run when conditions are
outside of the operating limits. Dehumidifiers are not as effective when conditions are outside
of the operating limits. For example, the dehumidifier will not remove much moisture when
conditions are cool and dry. Control limits allow the dehumidifier to work efficiently within the
operating range and turn off when conditions are outside of these limits.
Dew Point Lower Limit
FIGURE 3 – ON/OFF BUTTONS
FIGURE 4 – UP/DOWN BUTTONS
or
button will
FIGURE 5 – EXTERNAL
HUMIDITY SETTING SCREEN
40°F
Temperature High Limit
90-1636
99°F