About Subroutines

There are a host of functions available on the MicroMarque3S which, because they are not used frequently do not have
specific keys dedicated to them. Instead, they are accessed through the SHIFT+ENTER (SUBROUTINES) and perform
as a small part of the computer program. Having achieved their specific task they then return control to the main
program.
Some subroutines simply deliver data- usually to the display and their job is done; others require additional key inputs
to modify data that will affect the running of the entire system.

Running a Subroutine.

All subroutines are started in the same way:
Check that the MicroMarque3S is in Program mode- the red indicator on the indicator bar should be
illuminated. If it is not, run Subroutine 638 (functions in any mode) which toggles between Program
and Feeding modes.
Press RESET.
Press SHIFT+ENTER (SUBROUTINES). This means pressing and holding down the SHIFT key and then
pressing the ENTER key whilst the SHIFT key is still depressed. Then release the ENTER key and finally
the SHIFT key. This procedure is referred to as SHIFT+ENTER in the text.
The Yield/Flags window will clear to three underscore marks.
Key the number of the subroutine required. Ignore leading zeros.
Press ENTER.
If the subroutine requires additional key entries, follow the instructions on the following pages.
Press RESET to exit a subroutine.
Subroutine 2: Display the Software Version: Subroutine 2:
The program which 'drives' the MicroMarque3S is stored on a silicon chip inside the machine and is occasionally subject
to minor changes. When a change is made the Version Number of the software is updated; your current version may be
accessed through subroutine 2. This information is important if repairs are being carried out to the system.
The Software Version Number is displayed in the Yield/Flags window as three digits- 200 in the example. There is a
implicit decimal point after the first digit so the version is 2.00
?