ATI Technologies QC-201 Handbuch - Seite 6
Blättern Sie online oder laden Sie pdf Handbuch für Industrielle Ausrüstung ATI Technologies QC-201 herunter. ATI Technologies QC-201 17 Seiten. Tool changer
Manual, Tool Changer, QC-201
Document #9620-20-B-201 Base Tool Changer-12
No-Touch Zone
Model
Z Offset (Max)*
QC-201
Table 2.1 – Maximum Recommended Offsets Prior to Coupling
Notes: * Maximum values shown. Decreasing actual values will minimize wear during
coupling/uncoupling.
† Actual allowable values may be higher in some cases but higher offsets will increase
wear during coupling.
2.3.1
Pinnacle Park
1031 Goodworth Drive
X, Y and Z Offset
Figure 2.2—Offset Definitions
X and Y Offset
(Max)†
(mm)
(mm)
±1
±2
Tool Locating Features
The tool must be positively and repeatably located in the tool stand. A variety of
methods may be used to accomplish this. Whatever method is chosen it is important
that the required compliance or "float" be built into the locating system. A common
method is to use tapered dowel pins in holes. As the Tool Plate is lifted during
locking, the taper lets the tool float into its locked position even with small deviations
in robot position.
Other tool locating feature methods include balls and detents, dowel pins in notched
V-grooves, etc. Please consult ATI for recommendations or assistance with locating
feature design for your particular tooling.
Straight cylindrical dowel pins should not be used as they provide too much surface
engagement. During coupling and uncoupling the tool can bind on these pins due to
misalignment of the Master and Tool Plates.
Robot programming and locational repeatability are vital in tool pick-up and drop-off.
Apex, NC 27539
Tel: 919.772.0115
Cocking Offset
(Max)
(degrees)
±0.7
Fax: 919.772.8259
B - 6
Cocking Offset
(About X and Y)
Twisting Offset
(Max)
(degrees)
±1
www.ati-ia.com
Email: info@ati-ia.com