Electrolux 10 GN2/1 Handbuch - Seite 2
Blättern Sie online oder laden Sie pdf Handbuch für Gefrierschrank Electrolux 10 GN2/1 herunter. Electrolux 10 GN2/1 3 Seiten. Electrical combi oven, touch and digital
Auch für Electrolux 10 GN2/1: Installationshandbuch (34 seiten)
CONSTRUCTION
•
Internal and external finishing in 304
AISI stainless steel and backpanel in
galvanized steel.
•
High density polyurethane
insulation, 60 mm tickness, HCFC
free.
•
Environmentally friendly: R404a as
refrigerant fluid.
•
Developed and produced in ISO
9001 and ISO 14001 certified factory.
•
Inner cell with fully rounded corners.
•
Door equipped with removable
magnetic gasket with hygienic design.
•
Motors and fan waterproof
protected IP23.
•
Evaporator with antirust protection.
TECHNICAL DATA
Power supply
Productivity per cycle - kg.
NF Regulations - chilling / freezing
UK Guide lines - chilling / freezing
Gross capacity (D.I.N. 8952) - l.
Cooling unit
External dimensions - mm
width
depth/with open doors
height
Door hinges
Trays type
Max load capacity - trays h 65 mm - n°
Compressor power - HP
N° defrost in 24 hrs.
Refrigerant type
Refrigerant quantity - g.
Refrigeration power - W
Refrigerant power
at evaporation temperature - °C
Power - kW
installed-electric
Net weight - kg.
Power supply - V, phases, Hz
INCLUDED ACCESSORIES
1 SINGLE-SENSOR PROBE-BL.C/FREEZERS LW
ACCESSORIES
3-POINT-SENSOR PROBE-BL.C/FREEZERS LW
4 WHEELS FOR BLAST CHILLERS
60 MM PITCH SIDE HANGERS FOR 10X2/1 OVEN
80 MM PITCH SIDE HANGERS FOR 10X2/1 OVEN
KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW
KIT TO CONVERT TO 10X2/1 ROLL-IN RACK
PLASTIC COATED GRID-600X400 MM
PLASTIFIED GRILL RILSAN GN 2/1
PRINTER HACCP BASIC VERS-REF.ELECR.CONTR
SLIDE-IN RACK SUPP. BC+BCF 56KG 10 GN2/1
Electrolux Blast Freezers
Blast Chiller/ Freezer - 56 kg 10 GN2/1
•
Ventilator (fan) swinging hinged
panel for access to the evaporator for
cleaning.
•
Automatic heated door frame.
•
Thermostatic expansion valve to
optimize the cooling unit efficiency.
•
Adjustable feet 150 mm high.
•
Stand alone printer as accessory.
•
PC connection on request, gate RS
485.
INSTALLATION
•
No water connections required.
•
Waste water can be plumbed into
drain, but can also be collected in an
optional waste container.
Internet: http://www.electrolux.com/foodservice
RBC102
726046
Electric
43.2, 43.2
64, 56
560
Built-In
1000
1010, 1755
1640
Right Side
GN 2/1; 600x800
6
3
3/30'
R404a
3170
2540
-30
2.88
235
400 V, 3N, 50
1
880212
881097
922123
922117
880183
922202
880864
881030
881532
880075