Figure 3: Diagram of FFO50 FlexFire® Oxygen Fuel burner adjustment knob
8. Stop burner
1.
For temporarily shut down, the burner does not need to remove from the burner brick,
oxygen must continue to be supplied at the flow of 30 Nm
2. For long time shut down, the burner needs to be taken out.
Turn off the gas and oxygen shut-off valve closest to the burner.
3. Loosen the burner fixing clamp from the fixing bracket then remove burner.
4. Block the nozzle hole with high-temperature material to prevent heat leaking from burner
block opening.
Oxygen and gas to the burner are interrupted for more than 10-15 minutes, please remove the
burner. Adjust the burner, loosen the corresponding fixing bolts and re-lock after adjustment. Do
not remove the metal hose or locking device when the gas and oxygen are not completely closed.
When the burner is deactivated, keep the oxygen pipeline equipment clean and sealed to prevent
pollution.