a.
Side port firing
Vertical adjustment
4.3
Positioning burner bracket
Use the positioning tube (sold separately) to locate the bracket. The installation
position of the bracket should ensure that the center of the burner nozzle and the
sealing plate are coaxial and fit tight without gap.
Secure the bracket with all fixing bolts so that it cannot move
4.4
Burner data
Model
capacity MW
10G3000
0.6-3.0
10G6000
2.5-6.0
10G9000
5.0-9.0
Anderson Thermal Soluions(Suzhou)Co., Ltd
Anderson Thermal Solutions –FFA10 Burner Operation Manual
Horizontal adjustment
Figure 2. FlexFire® burner Adjustment Mechanism
Input
Nozzle OD Φ
(mm)
77
95
110
Gas flow
Pressure @
(NCMH)
burner (mbar)
Min
Max
Min
60
300
16
125
600
16
250
900
16
6
b. Under port firing
Cooling air
(NCMH)
Max
Min
Max
500
10
500
10
500
10
20
20