Bosch WTA74200AU Installationsanleitung Handbuch - Seite 3
Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Trockner Bosch WTA74200AU herunter. Bosch WTA74200AU 6 Seiten. Exhaust air duct for tumble dryer
Auch für Bosch WTA74200AU: Gebrauchsanweisung (10 seiten)
Contents
Safety instructions ........................................................................................................................ 1
Connections on the dryer ........................................................................................................... 2
Notes on installation .................................................................................................................... 3
Installation options ....................................................................................................................... 4
Notes on installation .................................................................................................................... 6
Installing more than one dryer ................................................................................................... 7
Safety instructions
- We recommend that you route the exhaust air directly into the open air through an exhaust
air duct.
- Where an exhaust air duct is routed to the open air, a drain check valve must be fitted
(prevents air from flowing back).
- Only install the air extraction system as described in these instructions.
- The air extraction system must not exceed the specified pressure losses, see page 3.
- Only use materials and parts specified in the instructions.
- Clean the exhaust air duct regularly, at least once a year.
When operating the dryer without an exhaust air duct, the following must also be observed:
- Ensure that the room is well ventilated, otherwise energy consumption and drying time will
increase.
- Ensure that the room is well ventilated
furniture.
- Do not cover the exhaust air opening (leave approx. 1 m of free space around the exhaust
air opening).
risk of damage caused by moisture, e.g. to walls,
Connections on the dryer
Connections for an exhaust air duct are located on the back panel and on the left side panel
of the dryer.
Back panel connection
1.
The exhaust air opening on the back panel is open when
the dryer is delivered (bayonet ring).
The exhaust air opening on the left side panel is sealed
with a cover.
Left side panel connection
2.
1. Remove the cover on the side panel.
2. Remove the bayonet ring from the back panel and attach
it to the opening on the side panel.
3. Seal the opening in the back panel with the cover.
Condensation outlet
If there is a high level of condensation in the exhaust air duct, it is advisable to fix
a condensation collector (standard) or a drain hole with a diameter of approximately 3 mm
to the lowest part of the exhaust air duct.