K8-series OEM Modules Commands Guide

2.12 Minimum SNR

Set minisnr param1
This command is used to set the minimum signal-to-noise ratio for tracking satellites.

2.13 Baudrate

Com param1 param2
This command is used to modify the baudrate of com port. A reboot operation is needed after giving this
command.

2.14 Interfacemode

Interfacemode comX <input-mode><output-mode> on
This command is used to setup input/output mode of comX port.
Mode
Auto
Compass

2.15 NMEA data output

Log comX gpgga ontime 1
Log comX gpgsv ontime 1
Tip: You can also output GSA, ZDA, RMC, GLL, NTR and other NMEA-0183 data.
//param: 9~37, default 15
//
Param1: com1/com2/com3
//Param2: 115200/230400/460800/921600
Description
The port supports receive/transmit RTCM, RTCM V3
The port supports receive/transmit ComNav command
//Output GPGGA
//Output GPGSV