Single Stall Installations
1.8L = Single Stall Urinal
The cistern is configured for single stall installations out of the factory.
The pneumatic tube must be connected to the full flush position.
= Full Flush Position
By adjusting the water level in the cistern up or down using the float
adjustment screw located on the side of the inlet valve, the flushing
volume may be fine tuned or reconfigured to any of the following flush
volumes.
2.3L = Single Stall Urinal
1.8L = Single Stall Urinal
1.3L = Single Stall Urinal
0.8L = Single Stall Urinal
45mm
335mm
access panel
centre line
copper pipe (supplied)
6
400mm - 420mm
Frame
to
Reducer to Ø40
Finished Floor Level
Refer to specifications of the selected urinal.
NOTE:
When installing the
Remote Mounting Box in
this position, please refer
to the 'Installation Note' on
page 5
Blank Access Panel
SIngle Remote Button
Centre Line Button
(standard mounting)
Datum
Ø20 sparge pipe
950mm
Recommended
Flush Volume & Stall Setup
Configuring Flush Volume
1
Remove Dust Cover and adjust Water
Level using the adjustment screw.
2
The Water Level should be set to
correspond to your required flush
volume marked on the inside of the
cistern.
90mm Min.
5mm Min.
Cavity Depth
45mm Max.
(70mm Min. for
inceiling
Cladding Thickness
installations)
Adjustment
Screw
Dust Cover