INSTALLATION AND OPERATION MANUAL
› For High Power Mode the power budgeted is based on ILIM/ICUT selected value.
· For ILIM/ICUT – 504/465 mA, the power budgeted is 22.5W
· For ILIM/ICUT – 563/545 mA, the power budgeted is 26.5W
· For ILIM/ICUT – 850/625 mA, the power budgeted is 31.6W
· For ILIM/ICUT – 850/725 mA, the power budgeted is 37.0W
» Dynamic /w Priority: The power is budgeted based on the load and priority of the port.
» Dynamic /wo Priority: The power is budgeted based on the Load.
ILIM/ICUT
Configuration:
Set the Current Limit and Current Cut Limit (ILIM/ICUT).
Status
Chip ID
Show the current PSE control Chip Revision.
SW Version
Shows the current running firmware version.
Max Ports
Shows the maximum number of Midspan ports detected by the software.
Power Available
Shows the total available power for the Midspan.
Power Allocated
Shows the total power allocated by the system. Power allocated varies based on the power
management mode selected.
Commands
Query
Click on the "Query" to updates the status fields.
Apply
Click on the "Apply" to configure the system with the inputted values.