Comnet FVT40D2I1C4E Installations- und Betriebshandbuch - Seite 5

Blättern Sie online oder laden Sie pdf Installations- und Betriebshandbuch für Medienkonverter Comnet FVT40D2I1C4E herunter. Comnet FVT40D2I1C4E 10 Seiten. 4-channel 10-bit digitally encoded video

LE-D
LE-D
LE-F
INSTALLATION AND OPERATION MANUAL
LE-F
ALARM
ALARM
S2
S2
FIGURE 6 – DATA SWITCH POSITIONS
IN
The mode for each data channel is configured using a set of two switches labeled DATA1 (S3) and DATA2 (S4), located on the front panel of the unit.
IN
OUT
OUT
DATA1
DATA1
S3
S3
IN
IN
OUT
OUT
DATA2
DATA2
S4
S4
ON
ON
FIGURE 7 – RJ-45 PIN OUT
PIN # RS232
1
NC
2
RS232 – OUTPUT
3
NC
4
RELAY OUT
5
RELAY OUT
6
RS232 – INPUT
7
GND
8
+5V (BIAS)
NC = No Connection
TECH SUPPORT: 1.888.678.9427
DATA1 (S3)
DATA2 (S4)
1
2
1
2
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
RS422
RS422 OUTPUT –
RS422 OUTPUT +
RS422 INPUT +
RELAY OUT
RELAY OUT
RS422 INPUT –
GND
+5V (BIAS)
Resulting Mode
RS232
RS422, Bi-Phase or Manchester
RS485 2-Wire, Sensornet
RS485 4-Wire
PIN # Wire Color
Data Connections
1
Blue
DATA OUT –
2
Orange
DATA OUT +
3
Black
DATA IN +
4
Red
RELAY OUT
5
Green
RELAY OUT
6
Yellow
DATA IN –
7
Brown
GND
8
White
+5V (BIAS)
RS485 2-Wire
NC
NC
RS485 INPUT +
RELAY OUT
RELAY OUT
RS485 INPUT –
GND
+5V (BIAS)
FVT/FVR40D2I1C4E
RS485 4-Wire
RS485 OUTPUT –
RS485 OUTPUT +
RS485 INPUT +
RELAY OUT
RELAY OUT
RS485 INPUT –
GND
+5V (BIAS)
INS_FVT/FVR40D2I1C4E_REVA 06/22/12 PAGE 5