Comnet EXP100C Installations- und Betriebshandbuch - Seite 7
Blättern Sie online oder laden Sie pdf Installations- und Betriebshandbuch für Extender Comnet EXP100C herunter. Comnet EXP100C 10 Seiten. Expansion module for use with fdw1000 wiegand module
Auch für Comnet EXP100C: Installations- und Betriebshandbuch (12 seiten)
INSTALLATION AND OPERATION MANUAL
FIGURE 7 – TYPICAL APPLICATION IN CONJUNCTION WITH FDW1000 GATEWAY SYSTEM
CENTRAL
FDW1000S1/C
Access
Control
EXP100/C
System
EXP100/C
EXP100/C
Access
Control
System
EXP100/C
FIGURE 8 – EXP100 CENTRAL INTERFACE
DC
Power
Supply
Access
Control
Panel
Additional EXP100/C
Modules
TECH SUPPORT: 1.888.678.9427
REMOTE
FDW1000S1/R
EXP100/R
EXP100/R
EXP100/R
EXP100/R
1 8 – 16VDC
1 8 – 16VDC
1 8 – 16VDC
2 GND
2 GND
RLY 4 N.O. 1
FDW1000 S
M
/C
FDW1000 S
M
2 GND
RLY 4 COM 2
FDW1000 S
CENTRAL
CENTRAL
RLY 4 N.C. 3
STATUS LED
STATUS LED
DATA
DATA
STATUS LED
RLY 3 N.O. 4
EXTENDER
EXTENDER
1 EXP(+)
RLY 3 COM 5
1 EXP(+)
1 EXP(+)
RLY 3 N.C. 6
2 EXP(–)
2 EXP(–)
2 EXP(–)
GND 7
3 +5V OUT
3 +5V OUT
3 +5V OUT
AUX OUT 8
4 PROG RES 2
4 PROG RES 2
4 PROG RES 2
RLY 2 IN 9
5 PROG RES 1
5 PROG RES 1
5 PROG RES 1
RLY 1 IN 10
6 LED IN
6 LED IN
6 LED IN
7 D1/DOUT
7 D1/DOUT
7 D1/DOUT
8 D0/COUT
8 D0/COUT
8 D0/COUT
1 8 – 16VDC
1 8 – 16VDC
1 8 – 16VDC
1 8 – 16VDC
EXP100/C
EXP100/C
2 GND
2 GND
2 GND
2 GND
CENTRAL
CENTRAL
EXPANSION
EXPANSION
STATUS LED
STATUS LED
STATUS LED
EXPANSION
STATUS LED
MODULE
MODULE
1 RS-485(+)
1 RS-485(+)
1 RS-485(+)
1 RS-485(+)
2 RS-485(–)
2 RS-485(–)
2 RS-485(–)
2 RS-485(–)
3
3
3
3
4
4
4
4
5
5
5
5
6 LED IN
6 LED IN
6 LED IN
6 LED IN
7 D1/DOUT
7 D1/DOUT
7 D1/DOUT
7 D1/DOUT
8 D0/COUT
8 D0/COUT
8 D0/COUT
8 D0/COUT
Card
Reader
Card
Reader
Card
Reader
Card
Reader
Card
Reader
1 8 – 16VDC
2 GND
RLY 4 N.O. 1
RLY 4 N.O. 1
/C
FDW1000 S
M
/C
RLY 4 N.O. 1
M
/C
RLY 4 COM 2
RLY 4 COM 2
CENTRAL
RLY 4 COM 2
CENTRAL
RLY 4 N.C. 3
RLY 4 N.C. 3
STATUS LED
DATA
RLY 4 N.C. 3
RLY 3 N.O. 4
DATA
RLY 3 N.O. 4
EXTENDER
RLY 3 N.O. 4
1 EXP(+)
RLY 3 COM 5
EXTENDER
RLY 3 COM 5
RLY 3 COM 5
RLY 3 N.C. 6
RLY 3 N.C. 6
2 EXP(–)
RLY 3 N.C. 6
GND 7
3 +5V OUT
GND 7
AUX OUT 8
AUX OUT 8
4 PROG RES 2
AUX OUT 8
RLY 2 IN 9
RLY 2 IN 9
5 PROG RES 1
RLY 2 IN 9
RLY 1 IN 10
RLY 1 IN 10
6 LED IN
RLY 1 IN 10
7 D1/DOUT
8 D0/COUT
1
1
1
EXP100/C
1
EXP100/C
2
2
2
CENTRAL
2
CENTRAL
3
3
3
EXPANSION
3
4
4
4
MODULE
4
MODULE
5
5
5
5
6
6
6
6
7
7
7
7
8
8
8
8
9
9
9
9
10
10
10
10
11
11
11
11
RLY 1 IN 12
RLY 1 IN 12
RLY 1 IN 12
RLY 1 IN 12
Wiegand Data
Optic Fiber
RS485 Link – Muti-drop
R1 Input
Controls Strike
on Remote
GND 7
FDW1000/C
EXP100/C
INS_EXP100_REV– 12/04/12 PAGE 7
EXP100