Drehmo 384771 Zusätzliches Betriebshandbuch - Seite 8
Blättern Sie online oder laden Sie pdf Zusätzliches Betriebshandbuch für Schalter Drehmo 384771 herunter. Drehmo 384771 12 Seiten. Simc with limit switching unit
Transmission ratio of limit
switch wheels
1:3 (SectionIII)
1:3 (SectionIII)
1:3 (SectionIII)
1:3 (SectionIII)
1:3 (SectionIII)
1:3 (SectionIII)
1:3 (SectionIII)
1:3 (SectionIII)
1:3 (SectionIII)
1:3 (SectionIII)
1:3 (SectionIII)
3:1 (SectionII)
3:1 (SectionII)
3:1 (SectionII)
3:1 (SectionII)
3:1 (SectionII)
3:1 (SectionII)
3:1 (SectionII)
3:1 (SectionII)
3:1 (SectionII)
3:1 (SectionII)
3:1 (SectionII)
Table 1.1: Setting the reduction gearing of the limit switching unit for multi-turn actuators
The values of the sliding wheel positions 1
Selection of the highlighted options is recommended and preferred.
NOTICE
If no stroke range is specified on the order, the reduction
gear will be preset at factory
8
Turns per travel (min. and
max.)
1.38
2.49
2.5
4.5
4.6
8.2
8.3
15
15.1
27.2
27.3
49.6
49.7
90.1
90.2
135
12.4
22.4
22.5
40.8
40.9
74.2
74.3
135
135
245
246
446
447
811
812
1450
For output speed of 5 50 turns/minute the factory setting is
section III
For output speed of 80 160 turns/minute the factory setting
is section II
1. COMMISSIONING
Position of sliding wheel
1
2
3
4
5
6
7
8
9
10
11
1
2
3
4
5
6
7
8
9
10
11
3 are available on request.