INSTRUCTIONS FOR THE INSTALLER
Gas connection
Make sure that the appliance is connected
according to the gas type available (see the
label under the appliance).
The appliance must be connected to the gas
system by means of stiff metal pipes or flexible
steel pipes having continuous walls, in
compliance with the regulations in force.
The connection must not stress the gas ramp.
When
making
towngas
EGC3310NOK1 and EGC3320NOK, ensure that
the accompanied external gas governor is properly
fixed (EGC3310NOK1 - governor's brand name:
ELITRE / model no. EL-125 at 10 mbar working
pressure) (EGC3320NOK - governor's brand
name: BECKLEY / model no. TG2355-00 at 8mbar
working pressure).
Use approved gas tubing bearing EMSD approval
marking (such as:
APPROVAL
GTXXXX)
appliances, or other appropriate methods accepted
by EMSD.
Once the installation is over, check the
connection seal with a soapy solution.
Electric connection
The connection to the electric grid must be carried
out by qualified personnel and in conformity with
the regulations in force.
The voltage of the electric system must correspond
to the value indicated in the label under the
appliance. Make sure that the electric system is
provided with an effective ground connection
in compliance with the regulations and provisions
of the law. Grounding is compulsory.
This device must be at a suitable opening distance
from the contacts in order to allow the entire
disconnection in case of overvoltage category III,
in accordance with installation rules.
connection
機 電 工 程 署 批 准
for
connection
Burners adjustment
The lowest flame point must always be properly
adjusted and the flame must remain on even if
there is an abrupt shift from the maximum to the
minimum position.
If this is not so, it is necessary to adjust the lowest
flame point as follows:
- start the burner up
- turn the tap up to the minimum position (small
flame)
- remove the knob from the tap rod
for
- introduce a flat-tip screwdriver in the hole F of the
tap (fig.7-7/A) and turn the by-pass screw up to a
proper adjustment of the lowest flame point.

MAINTENANCE

Replacing the power supply cable
EMSD
If the power supply cable should be replaced,
to
it is necessary to use a cable with a section of
2
3x0.75mm
, type H05VV-F or H05RR-F, complying
with the regulations in force.
The connection to the terminal board must be
effected as shown in fig.8:
brown cable L
blue cable N
green-yellow cable
CARE
The panel of this built-in hob is made of ceramic glass
which is safer than normal glass for this application.
However, the following safety precautions for using
built-in hob with glass top panel should also be noted
in order to prevent the glass top panel from breaking:
- Clean the burner assembly frequently to maintain a
clear gas passage on the flame distributor. Clean and
tidy up the flame distributor after spillage of food and
liquid once the burner assembly cooled down.
- Turn off the gas appliance immediately if abnormal
noise propagates from the gas appliance and contact
gas supply company or gas hob importer for
inspection.
- Do not use oversized utensils for cooking.
- Do not impact the glass surface with hard objects or
place heavy objects on the glass surface.
5
(phase)
(neutral)
(ground)