Electrolux EGC3310NVK Benutzerhandbuch - Seite 9
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Kochfeld Electrolux EGC3310NVK herunter. Electrolux EGC3310NVK 20 Seiten.
When you assemble each
burner, use the special cap
tool (C) and a screwdriver to
prevent damage to the nuts.
C
B
A
Triple Crown: screw on the nuts with the
diameter of 16 mm (B), included in the
supply (primary air regulators).
Be sure to remove the cap
tool before reassembling the
burners.
3.5 Adjustment of minimum
level
To adjust the minimum level of the
burners:
1. Light the burner.
2. Turn the knob on the minimum
position.
3. Remove the knob.
4. With a thin screwdriver, adjust the
bypass screw position (A).
A
5. If you change:
• from liquid gas to town gas G110
14mbar, undo the bypass screw
approximately 3/4 of a turn for
Triple Crown burner.
• from town gas G110 14 mbar to
liquid gas, fully tighten the bypass
screw in.
WARNING!
Make sure the flame does
not go out when you quickly
turn the knob from the
maximum position to the
minimum position.
3.6 Replacing the power supply
cable
Use the same type of power supply
cable. This cable must be connected to
the terminal block following the diagram.
230V~
If the power supply is
damaged it must be
substituted by a suitable
cable available in the after
sales service.
Connection to a good earth
wiring system is absolutely
essential. The manufacturer
accepts no responsibility for
any inconvenience caused
by failure to comply with this
rule.
If the power supply cable has to be
replaced, the gauge of the wires in the
new cable must be at least 0.75 mm² (3 x
0.75 cable), the earth wire (yellow-green)
must be at least 20 mm longer at the end
for connection to the appliance.
ENGLISH
9