manual
Lid lock
The lid is mounted on an arm and closes onto
1
the deck of the outer casing.
The extractor is closed by first moving the lid
over the drum and then pressing the arm
downwards. The arm activates a mechanical
lid lock which prevents the lid from being opened
during extraction.
To prevent the machine from being able to start
with the lid open there is a microswitch which
detects when the lid lock is engaged. Reed
elements in the lid (on the C240/C240R and
C260/C260R) sense when the lid is pressed
down towards the deck.
The lid lock is opened by activating a traction
magnet which releases the mechanical lock.
For it to be possible to open the lid, the machine
needs to be supplied with power and the
machine´s mechanical rotation guard and the
motor´s Hall element need to have given the
opening signal (drum not rotating).
The lid opened by pressing the
moving the arm to one side.
487 03 29 91

29. Lid and lid lock

button and
1
CP
Micro Switch
SW1
29
Arm
Traction
magnet
Lid
lock
29.1