Atlantic alfea S5 Betriebshandbuch - Seite 15

Blättern Sie online oder laden Sie pdf Betriebshandbuch für Wärmepumpe Atlantic alfea S5 herunter. Atlantic alfea S5 16 Seiten. Alféa s series heat pump air/water split, single service

Split system
3.7

Information display

Various data can be displayed by pressing the info
button.
Depending on the type of unit, configuration and
operating state, some of the info lines listed below may
not appear.
- Possible error messages from the error code list. The
display shows the "Bell" symbol
" Consult your heating technician.
- Possible service messages from the maintenance
code list. The display shows the "Key" symbol
" Consult your heating technician.
- Possible special mode messages. The display shows
the "Key" symbol
.
" Consult your heating technician.
Various data (See below).
Designation
Floor drying current setpoint .
Current drying day.
Terminated drying days.
State heat pump.
State supplementary source.
State DHW.
State swimming pool.
State heating circuit 1.
State heating circuit 2.
State cooling circuit 1.
Outdoor temperature.
Room temperature 1.
Room setpoint 1.
Flow temperature 1.
Flow temperature setpoint1.
Room temperature 2.
Room setpoint 2.
Flow temperature 2.
Flow temperature setpoint 2.
DHW (domestic hot water) temperature.
Heat pump return temperature.
Setpoint (return) HP.
Heat pump flow temperature.
Setpoint (flow) HP.
Swimming pool temperature.
Swimming pool temperature setpoint.
Operation manual "1328 - EN"
.
.
3.8
If the electrical power supply has been cut off while
the heat pump is operating (electrical power failure or
unprogrammed pressing of the on/off switch on the
hydraulic unit) the display will show error 370 when the
appliance restarts.
Do not be concerned, the communication between the
outdoor and hydraulic unit will re-establish itself in a few
Line
moments.
-
3.9
-
-
The key enables you to
switch the DHW (domestic
8006
hot water) mode on and
8022
off (If the installation is
8003
fitted with a DHW tank with
electrical back-up heating).
8011
The selection is shown by
8000
a bar, which appears under
8001
the corresponding symbol.
8004
8700
Press the info key
obtain the details on the
8740
DHW (temperature setting
operation).
To ensure a DHW setting over 45°C, the electrical
8743
backup heating or the boiler must be left on.
8770

3.10 Selecting cooling mode

If the installation is fitted with
8773
the cooling kit.
The
8830
deactivates cooling mode.
8410
8412
8900
Brief
press
Details of any error
Operating values
...
figure 9 - Information key

Details

Operation of the DHW system

to
key
activates
and
figure 10 - Selecting
the DHW operating mode
(domestic hot water)
figure 11 -
Selecting cooling mode
- 15 -