Electrolux ERHC1238S Installations- und Benutzerhandbuch - Seite 7
Blättern Sie online oder laden Sie pdf Installations- und Benutzerhandbuch für Lüftungshaube Electrolux ERHC1238S herunter. Electrolux ERHC1238S 16 Seiten. Canopy cooker hood
Auch für Electrolux ERHC1238S: Installations- und Benutzerhandbuch (14 seiten)
COOKER HOOd INSTALLATION (CONT)
If additional or alternative mounting points are required
there are 4 x m10 threaded mounting points on the top of
the cooker hood as highlighted in the image below.
m10
4. Prior to installing the cooker hood into position,
fix exhaust transition duct using screws supplied,
ensuring the seal is between the cooker hood top
panel and the base of the exhaust transition (Fig. d).
4a. I f required, fit the dampers and secure with clamps,
duct tape or cable ties.
Transition pieces
ERHC1238S - 1200mm model
Transition piece
screw holes (4 places)
d5
Fig. C
Fig. D
5. mounting and securing the transition pieces is shown
in Fig. d.
WarnIng!
Use screws provided to secure transition piece at
preformed holes. Using alternate screws and hole
locations may cause an electricl safety risk.
6. Hang hood on the mounting screws, tighten mounting
screws then secure at the anti-tilt locations as
indicated in Fig. B.
WarnIng!
Due to product weight, take appropriate measures to
lift and position the product to avoid injury.
7. The canopy cooker hood has been supplied with duct
transition piece/s, 200mm diameter non-combustible
flue pipe must be used with the transition piece/s.
Continue the centre line to the ceiling. Fit preferred flue
pipe to the fan transition duct (Fig. d1 & d2,
see page 11).
Use worm drive clamps, cable ties or suitable duct tape to
secure flexible pipe to the transition duct.
NOTE: We recommend extending flue pipe through the
roof to external roof cowl to vent exhaust externally.
We do not recommend venting into ceiling cavity.
NOTE: To ensure optimum performance of the cooker
hood, the use of 200 mm diameter rigid ducting is
recommended. The use of bends should be avoided.
Rigid flexible ducting is suitable, although loose flexible
ducting is unacceptable. All ducting must be fire retardant.
electrical connection
Check that the installation complies with the standards
of local building, gas and electrical authorities. Before
connecting to the mains supply ensure that the mains
voltage corresponds to the voltage on the rating plate
inside the cooker hood.
d6
7