Atlantic Ultraviolet BIO 1.5 Installation, Betrieb und Wartung - Seite 13

Blättern Sie online oder laden Sie pdf Installation, Betrieb und Wartung für Water Filtration Systems Atlantic Ultraviolet BIO 1.5 herunter. Atlantic Ultraviolet BIO 1.5 16 Seiten. Ultraviolet water purifiers

D
M

ISPOSAL OF

ERCURY
Germicidal ultraviolet lamps, like standard fluorescent lamps contain small amounts of mercury. Mercury added
lamps should not be placed in the trash. Dispose of properly. For further information regarding the disposal and
recycling of lamps containing mercury, along with Federal and State requirements visit http://www.lamprecycle.org.
Product Data Sheets for germicidal ultraviolet lamps can be found in the "PDF Library for Ster-L-Ray
Ultraviolet Lamps" section of http://www.ultraviolet.com.

TROUBLESHOOTING

WARNING: Always disconnect power to the water purifier before performing any service or maintenance.
IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel.
Problem
Purifier not operating
Water leaking into/from purifier.
Poor purifier performance.
B
N
. 10-0518A
ALLAST
O
If power is applied to the ballast without a lamp connected to the circuit or if the lamp fails, the ballast's lamp-out protection
will prevent the ballast from operating, and a red LED light will illuminate and audio alarm will sound. To reset: disconnect the
ballast from power and reconnect or replace the lamp. The ballast must remain disconnected from power for (2) minutes to
reset. After 2 minutes restore input power, ballast should resume proper operation.
WARNING: The equipment that this ballast is used with requires connection to a known good ground. It is the User's
responsibility to insure that their equipment is properly grounded in compliance with the National Electrical Code and
any applicable local codes. Equipment wiring and hook up should be performed by a qualified, licensed electrician.
Failure to comply with this requirement could result in serious injury or death.
A
L
DDED
AMPS
Table 3 - Troubleshooting
Possible Cause
No electrical power....
Cracked or broken quartz sleeve...
Quartz sleeve sealing o-ring (s) worn,
damaged...
Poor, or loose, connections or fittings
Quartz sleeve fouled...
Germicidal lamp output depreciating...
Germicidal lamp not functioning...
Low input voltage...
Change in water quality....
10-0514A
AND
HAVE
Corrective Action
Verify that the purifier is connected to a live power
source.
Shut down purifier, drain, and replace quartz
sleeve. See "Quartz Sleeve Installation, Cleaning
or Replacement" or "Replacement of Broken
Quartz Sleeve" in the "Maintenance" section
Shut down purifier, drain, and remove static gland
nut, replace sealing o-ring. See "Quartz Sleeve
Installation, Cleaning or Replacement" in the
"Maintenance" section
Tighten suspect connection or fitting; or shut down
purifier, drain, and remove fitting or connection.
Clean threads; reapply thread sealing tape and
reinstall.
Clean quartz sleeve, see "Quartz Sleeve
Installation, Cleaning or Replacement" in the
"Maintenance" Section.
Replace lamp, as it nears its end of life (EOL).
See "Lamp Installation or Replacement" in the
"Maintenance" section.
Replace lamp. See "Lamp Installation or
Replacement" in the "Maintenance" section
Verify input voltage to purifier.
Have water tested to confirm that it does not
exceed maximum recommended concentration
levels for use with this purifier.
L
-
P
AMP
OUT
ROTECTION
®
Germicidal
13