Atlantic Ultraviolet Sanidyne PREMIUM Benutzerhandbuch - Seite 15

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Zubehör Atlantic Ultraviolet Sanidyne PREMIUM herunter. Atlantic Ultraviolet Sanidyne PREMIUM 20 Seiten. Germicidal ultraviolet portable area sanitizer

Atlantic Ultraviolet Sanidyne PREMIUM Benutzerhandbuch

TROUBLESHOOTING

Always disconnect power to the fixture before performing any service or maintenance.
IN ORDER TO PERFORM THIS TASK, WEAR PERSONAL PROTECTION EQUIPMENT; GLOVES,
LONG SLEEVE SHIRT WITH NO GAPS BETWEEN CUFFS AND GLOVES, AND AN ULTRAVIOLET
BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN.
IMPORTANT: This fixture is to be serviced ONLY by qualified and factory authorized personnel.
Problem
Possible Cause
Power disconnected
Sanidyne
Premium
®
not operating
Fuse not operating
STER-L-RAY
Germicidal lamp faulty
STER-L-RAY
Lamp not operating
lamp not properly seated
Loose Connection
Surelite
Sanidyne
Premium
Microprocessor
®
fails to shut off
assembly faulty
Cooling fan
Fan failure
not operating
Low air flow through
Fan filter clogged
cooling fans

TECHNICAL SPECIFICATIONS

Model:
Voltage: (v)
Amperage: (A)
Hertz: (Hz)
Maximum Treatment Time: (Hours)
Weight: (Pounds)
Length: (Inches)
Dimensions:
Width: (Inches)
Height: (Inches)
Lamp Model:
Number of Lamps:
Lamp Data:
Power Consumption:  (Watts per Lamp)
Ultraviolet Output:  (Watts per Lamp)
Average Effective Life: (Hours)
Wattage is lamp watts only and does not include ballast loss.
 Ultraviolet output at 254nm at 100 hours and 80 °F (approximate).
All specifications, dimensional data, etc are approximate and subject to change without notice.
Table 1 – Troubleshooting
Corrective Action
Check connections.
Remove power connector to check and
replace fuse if necessary.
Swap suspect lamp, with lamp known to be good.
®
If suspect lamp does not operate, replace lamp.
Germicidal
®
Check lamp socket and re-install lamp if necessary.
Inspect for loose or disconnected wires.
Ballast not operating Disconnect the fixture from utility power; then replace ballast.
Wearing protective clothing and face shield, enter area, and
disconnect power to unit. Call factory for technical service.
Check fan connections and replace if it does not operate.
Remove filter and clean. Replace if filter appears worn or old.
Table 2 – Technical Specifications
40-5240C
120v
16A
50/60 Hz.
24 Hours
76 lbs.
21-3/4"
20-15/16"
68-1/2"
05-0250
8
176W
60 UV Watts
13,000 Hours
15