Atlas Diane AC-MGB2 Anleitung Handbuch - Seite 3
Blättern Sie online oder laden Sie pdf Anleitung Handbuch für Fan Atlas Diane AC-MGB2 herunter. Atlas Diane AC-MGB2 9 Seiten. Ceiling mounted oscillating directional fan ac 120v. 60hz
READ AND SAVE THESE SAFETY AND INSTAllATION
Consult a licensed electrician if unsure of any point below mentioned.
1. High voltage and moving parts around motors and motor driven equipment can cause serious
or fatal injuries. Always disconnect power source at main switch before wiring, servicing or
cleaning unit. Do not rely on fan control device to prevent unexpected start-up or electrical
shock. In addition, power supply must have fuses or circuit breakers for short circuit protection.
2. All electrical wiring must conform to national and local electrical codes such as: NEC, OSHA,
etc.
3. Fan should be secure in its electrical grounding to avoid possible electrical shock.
4. Fan should not be used in any wet or hazardous location defined by article 500 of the NEC. In
addition, its ambient temperature should not exceed 104 degrees Fahrenheit.
5. Power supply should conform to voltage rating of 120V.
6.
Before applying power, visually re-inspect the installation. Make sure that all guards and
protective devices are securely in place and all visible screws and bolts are tightened.
7. Warning: to reduce the risk of fire, electrical shock or personal injury, mount hanging bracket to
outlet box marked "Acceptable for fan support and a hanging weight of 45 Lbs." Do not mount
fan to sheet rock or drywall type materials and use only the screws provided with the outlet box.
8. Caution: to reduce the risk of injury to persons, install fan so that bottom edges of fan blades are
to be:
**In Canada, to satisfy CSA requirements: at least 8.3 Ft/2.5 M above the floor and all objects in
room if safety cages are utilized. 10,0 Ft if safety cages are not utilized.
**In the US, to satisfy UL requirements: at least 7.0 Ft above the floor and all objects in room if
safety cages are utilized. 10.0 Ft. if safety cages are not utilized.
9. To reduce the risk of personal injury, do not bend blades or any other part of fan when cleaning.
Do not insert foreign objects in between rotating fan blades or in space surrounding entire
rotating fan unit. Fan must be turned off at power at supply source before installation, cleaning
or servicing.
10. Instructions for Supply Connections:
to be connected to a grounded conductor of a power supply, conductor of fan identified as
ungrounded conductor to be connected to an ungrounded conductor of a power supply,
conductor of fan identified for equipment grounding to be connected to an equipment-
grounding conductor. After making the wire connections in junction box, the splices should be
turned upward and pushed carefully into the outlet box. The wires should be spread apart with
the grounded conductor and the fan-grounding conductor on one side of the junction box and
the ungrounded conductor on the other side of the outlet box. Be sure that all wiring
connections are properly insulated from each other and any surrounding metal parts.
safety and best operating results, we recommend that you have a qualified electrician
assemble and install your fan.
INSTRUCTIONS.
DANGERIW ARN ING/CA UTION
Conductor of a fan identified as grounded conductor
2
For