Bose Lifestyle 28 Handbuch zur Fehlersuche - Seite 14

Blättern Sie online oder laden Sie pdf Handbuch zur Fehlersuche für Home Theater System Bose Lifestyle 28 herunter. Bose Lifestyle 28 32 Seiten. Dvd home entertainment systems
Auch für Bose Lifestyle 28: Installationshandbuch (32 seiten), Betriebshandbuch (44 seiten), Benutzerhandbuch (22 seiten), Betriebshandbuch (46 seiten), Betriebshandbuch (44 seiten), Betriebshandbuch (34 seiten)

Bose Lifestyle 28 Handbuch zur Fehlersuche
The unit boots into SmartSpeaker mode by default and can be put into TAP mode via two different
methods:
Send out the following 4 bytes using a RS-232 terminal (4800 baud, 8 bits, no parity, 1 stop bit):
0x01,0xFF,0xAA,0x54. This tells the board to switch to ASCII TAP mode. The board will then switch
protocols to 4800 baud, 8 bits, even parity, 1 stop bit. It will reply with a single '>' (0x3E). Since the
response is 0x3E, the parity bit will be set to 1; there is no need to switch protocols until after the
'>' is received since the parity bit will look like a stop bit. Switch the RS-232 terminal to 4800 baud,
8 bits, even parity, 1 stop bit. At this point, normal ASCII TAP commands can be sent to the board.
Note that when TAP mode is activated in this manner, the DSP will not echo characters sent by the
terminal.
Set all four DIP switches into the "up" position (away from RCA plugs). Power the PS28 up using
the AC line switch and wait until the amber LED blinks twice and the green LED blinks briefly at
least once (approx. 3 seconds after power up). Then, within twenty seconds, flip ALL four switches
down, then flip switch #4 (closest to the RJ-45 connector) back up. The unit will now communicate
in TAP mode. Note that when TAP mode is activated in this manner, the DSP will echo characters
sent by the terminal.
2.5 Thermistor Temperature Sensor
Sheet 8 of SD254175
RT600 is a negative temperature coefficient device which is used to measure the ambient tem-
perature in the vicinity of the DSP. This measured temperature is used by the DSP in a complex
algorithm which uses the woofer output signal and the PSC_PWM signal (which contains info
about the power supply rail voltage) to compute the power being dissipated in the MOSFETs on
the Power Supply PCB and, hence, their approximate temperature, then adjusts the system gain
over time to keep the unit's operating temperature within safe limits despite the external ambient
temperature or how long/loud the unit has played. This algorithm only "turns the volume down" by
a few dB in cases where the unit has been operated at maximum volume levels with "heavy"
source material.
The resistance of RT600 changes inversely proportional to the temperature of the device, with its
resistance nominally 10k at room temperature (25°C). The circuit formed by two of the comparator
sections of U3 and the associated parts form an oscillator which has an "on" time determined by
C620 charging through R655 and an "off" time determined by C620 discharging through RT600.
This makes the oscillator output a waveform with a duty cycle that is a function of the temperature
of RT600. The DSP samples the output of the oscillator at a constant rate and averages the total
"on" time and total "off" time over 10 cycles of the oscillator to compute the temperature.
2.6 DIP Switches
Sheet 8 of SD254175
The 4-position DIP switch S1 is primarily on the DSP to set the room code of the bass module for
situations where there are multiple speakers on a single zone of a Lifestyle
switches normally ship with all four in the "down" position (towards the PCB). They also serve as a
method of setting the Sharc into TAP mode, but only during the first 20 seconds after power has
been turned on.
Theory of Operation
14
PS18/28/35 Troubleshooting Guide
®
media center. These