15. A.
Complaint:
DRYER NOT OPERATING:
FAILURE TO SWITCH ALARM (Optional):
OUTLET DEWPOINT HIGH:
MOISTURE DOWNSTREAM:
EXCESSIVE AIR LOSS ON REGENERATING TOWER:
EXHAUST VALVE LEAKING DURING
REPRESSURIZATION:
EXCESSIVE PRESSURE DROP:
AIRTEK
4087 WALDEN AVENUE, LANCASTER, NY 14086

TROUBLE SHOOTING GUIDE:

Possible Cause & Repair:
A: No Lights On:
B: Lights On, Dryer Does Not Switch:
-
Blown control fuse: Replace fuse.
-
No power: Apply correct power.
-
Solid State Controller inoperative: Replace
-
Dryer in PowerLoc Mode
-
Dryer in CycleLoc Mode
-
Time delay setting too short. Adjust properly.
-
See dryer not operating
-
Dryer not cycling: See Dryer not operating.
-
Incorrect purge rate: Adjust purge flow.
-
Capacity of dryer being exceeded: Adjust inlet
flow, pressure & temperature to within specified
operating parameters. High flow, low pressure or
high temperature will all adversely effect dryer
performance
-
Liquid water present at dryer inlet: Check water
level in separators, receivers, prefilters &
operation of associated y-strainers and auto
drains. Check condition of filter elements or
check D.P. Gauges.
-
Desiccant worn out, contaminated or insufficient
quantity: Replace or top off.
-
Back pressure in regenerating tank: See below.
-
Leaking bypass valve: Remedy.
-
Undried air from another source mixing down
stream of dryer: Remedy.
-
See Outlet Dewpoint High.
-
Purge set too high. Check specifications &
adjust.
-
Check valve leaking: Repair, clean or replace.
-
Inlet valve leaking or not functioning: See Below
-
Defective controller: Repair or replace.
-
Valve dirty or defective: Clean or replace valve.
-
False signal from control board: replace
-
Prefilter dirty: Replace element
-
Afterfilter dirty: Replace element
-
Desiccant dirty: Replace Desiccant
-
Excess flow: Reduce flow to within specs.