DROPSA 3416 Series Benutzer- und Wartungshandbuch - Seite 6
Blättern Sie online oder laden Sie pdf Benutzer- und Wartungshandbuch für Water Pump DROPSA 3416 Series herunter. DROPSA 3416 Series 6 Seiten.
12. HANDLING AND TRANSPORTATION
Prior to shipping, pumps are packed and in cardboard containers. During transportation and storage always maintain the pump
the right way up as indicated on the box.
On receipt check that the packaging has not been damaged and store the pump in a dry place.
Given the low weight and the small dimensions, the pump may be handled without any special lifting apparatus.
13. OPERATING HAZARDS
It is necessary to read and understand the possible hazards and risks involved when using a lubrication pump.
The operator must fully understand the hazards implied in pumping grease under pressure.
Flammability
The lubricant generally used in lubrication systems is not normally flammable. However, it is desirable to avoid contact with
extremely hot substances or naked flames.
Pressure
Prior to any intervention, check the absence of residual pressure in any branch of the lubricant circuit as it may cause oil sprays
when disassembling components or fittings.
Spring
Be careful! Pre-loaded spring in the reservoir.
14. PRECAUTIONS
No particular operating hazards characterize these pumps, except for the following precautions:
•
Operator's contact with lubricant in case of piping breaking/opening or during refill/maintenance. -> Protection
against direct and indirect contact with the fluid must be provided by the user: the operator must be provided with
suitable individual protective clothing and devices.
•
Use of incompatible lubricant -> Main incompatible fluids:
Lubricants containing abrasive components
Lubricants containing silicon
Petrol – solvents – inflammable liquids
Corrosive products
Water
Food Products
6
Fluid
⇓
Premature wear of pump
Pump failure
Fire – explosion –seal damage
Pump damage - danger to persons
Pump oxidization
Contamination of the product
Danger