ELEKTRA OCD4 Benutzerhandbuch - Seite 3

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Thermostat ELEKTRA OCD4 herunter. ELEKTRA OCD4 4 Seiten.

Type OCC4/OCD4
Temp
Time
Min
5.0°C
25°C
40.0°C
06:00
OK

User settings

In the user settings menu you can change the
following items:
• Time and date
• Child lock

• Display settings

• Event schedule
• Energy monitor
Time and date
Press OK and set the actual time in hours
and minutes.
The date will then be displayed. Set the date
and confirm with OK.
Child lock
Allows you to lock the thermostat settings,
e.g. in public or other places where you do
not want the settings changed.
Press OK and set the child lock to On using
the down button. Confirm with OK.
The child lock can be unlocked by pressing both the Comfort and
Manual buttons simultaneously for 5 seconds.
Display settings
Allows you to select what is shown on the
initial display.
Time/day: Shows the actual time and day
at the top of the display.
Set temp.: Shows the current temperature setting.
Act. temp.: Shows the actual measured temperature.
Scr. saver: Switches off the display after 30 seconds if no button is
pressed. Any subsequent press of a button reactivates
the display. The thermostat remains on and runs the
selected program.
Press the OK button to select or deselect the display options. Then
select Exit in the menu to return to the initial display and view your
chosen settings.
Event schedule
Allows you to choose the type of weekly
event schedule you require.
5:2 4-event : Monday to Friday with 4 events
and Saturday to Sunday with 2
events.
Typically used if you work from Monday to Friday.
6:1 4-event : Monday to Saturday with 4 events and Sunday with
2 events. Typically used if you work from Monday to
Saturday.
7:0 4-event : Monday to Sunday with 4 individual events. Allows
you to choose individual programs for each of the 7
days of week.
5:2 6-event : Monday to Friday with 6 events and Saturday and
Sunday with 2 events. Typically used if you work
from Monday to Friday.
6:1 6-event : Monday to Saturday with 6 events and Sunday with
2 events. Typically used if you work from Monday to
Saturday.
7:0 6-event: Monday to Sunday with 6 events. This allows you
Max
05:00
08:00
OK
User settings
OK
Time and date
OK
Child lock
OK
Display settings
OK
Event schedule
OK
© 2014 OJ Electronics A/S
to choose individual programs for each day of the
week.
0:7 6-event: Monday to Sunday with 6 events and the same
program for all days of the week.
Select the required event schedule and confirm with OK.
For instructions on programming the time and temperature for the
event schedule, see event settings.
Energy monitor
Allows you to view energy consumption for
the past 2 days, 30 days or 365 days.
Press OK for the chosen period. The value
in per cent (%) shows the relative amount of
time the heating has been on. The following figure is the cost for the
selected period. To ensure correct calculation, check the settings for
currency, price per kWh and load.
Currency: Press OK and chose the required currency.
Confirm with OK.
Cost/unit: Press OK and set the actual cost of electricity.
The cost must be entered per kWh. Press OK.
Load:
Press OK and enter the connected heating power.
The value must be in watt (W). Press OK.
Leave the menu by pressing Exit.
Engineer settings
The Engineer settings menu contains the
following options:

• Offset temperature

• Adaptive function

• Application
• Temperature scale
• Display illumination
• Selecting the sensor
• Language
• Factory reset
• Information
Offset temperature
If the actual measured temperature does not
corresponding to the thermostat value, you
can adjust the thermostat by offsetting the
temperature.
Press OK and enter the value of the measured temperature. Confirm
with OK.
Adaptive function
Ensures that the required temperature has
already been reached when you get up in the
morning or come home from work. After just
a few days, the adaptive function will have
automatically calculated when the heating must be turned on.
Press OK and set the function to On. Confirm with OK.
Application
Set the type of regulation used.
There are 4 options:
Floor reg. :
The thermostat regulates floor
temperature only. A floor sen-
sor must be connected.
Room reg. : The thermostat regulates room temperature only.
Room/limit : The thermostat regulates room temperature with min.
and max. limits for floor temperature. A floor sensor
must be connected.
Regulator :
The thermostat functions as a simple regulator and no
sensors are used. The setting is a percentage.
English
Energy monitor
OK
Engineer settings
OK
Offset temp.
OK
Adaptive function
OK
Application
OK
3