DROPSA 0086450 Benutzer- und Wartungshandbuch - Seite 3

Blättern Sie online oder laden Sie pdf Benutzer- und Wartungshandbuch für Inverter DROPSA 0086450 herunter. DROPSA 0086450 8 Seiten. Hydraulic inverter

4.1 Hydraulic system
Exchange line 1->2 (fig.2) - when fluid reaches the adjusting spring pressure
calibration "PS1", the pilot conduit opens causing the displacement of the
chamber from the position "b" to the position "a"
Exchange line 2->1 (fig.4) - when fluid attains the adjusting spring pressure
calibration "PS1", the pilot conduit opens causing the displacement of the
chamber from the position "a" to the position "b"
Activation line 1 (fig.1) - with valve in position "a" the pump pushes lubricant
to line 1. Line 2 is discharge phase.
Fig.1
Activation line 2 (fig.3) - with valve in position "b" the pump pushes lubricant to
line 2. Line 1 is discharge phase.
Fig.3
Fig.2
Fig.4
3