DRY AGER DX 1000 Betriebsanleitung - Seite 6
Blättern Sie online oder laden Sie pdf Betriebsanleitung für Kühlschrank DRY AGER DX 1000 herunter. DRY AGER DX 1000 17 Seiten.
Auch für DRY AGER DX 1000: Benutzerhandbuch (14 seiten)
- 1. Disposal Notes
- 2. Saving Energy
- 3. Description of the Appliance
- 4. Integrated Systems
- 5. Safety Instructions and Warnings
- 6. Electrical Connection
- 7. Interior Light
- 8. Safety Lock
- 9. Display and Symbols
- 10. Key Combination
- 11. Error Messages
- 12. Alarm Acknowledgement
- 13. Changing over Door Hinges
- 14. Shutting Your Appliance down
Safety Instructions and warnings
• To prevent injury or damage to the unit, the appliance should
be unpacked and set up by two people.
• In the event that the appliance is damaged on delivery, contact
the supplier immediately before connecting to the mains.
• To guarantee safe operation, ensure that the appliance is set up
and connected as described in these operating instructions.
• Disconnect the appliance from the mains if any fault occurs.
Pull out the plug, switch off or remove the fuse.
• When disconnecting the appliance, pull on the plug, not on
the cable.
• Any repairs and work on the appliance should only be carried
out by the customer service department, as unauthorised
work could prove highly dangerous for the user. The same
applies to changing the mains power cable.
• Do not allow naked flames or ignition sources to enter the
appliance. When transporting and cleaning the appliance,
ensure that the refrigerant circuit is not damaged. In the
event of damage, make sure that there are no ignition sources
nearby and keep the room well ventilated.
• Do not stand on the plinth, drawers or doors or use them to
support anything else.
• This appliance can be used by children of 8 years old and
over, and also by persons with restricted physical, sensory
or mental capacity or lack of experience and knowledge, if
they are supervised or have been instructed on safe use of
the appliance and understand the resulting risks. Children
must not be allowed to play with the appliance. Cleaning and
user maintenance must not be carried out by children without
supervision.
• Avoid prolonged skin contact with cold surfaces or chilled/
frozen food. This could cause pain, numbness and frostbite.
In the case of prolonged skin contact, protective measures
should be taken, e.g. gloves should be worn.
• Do not consume food which has been stored for too long, as
it could cause food poisoning.
• Do not store explosives or sprays using combustible propel-
lants such as butane, propane, pentane, etc. in the appliance.
Electrical components might cause leaking gas to ignite. You
may identify such sprays by the printed contents or a flame
symbol.
• Do not use electrical appliances inside the appliance.
• If you have a lockable appliance, do not keep the key near
the appliance or within reach of children.
• The appliance is designed for use in enclosed areas. Do
not operate the appliance outdoors or in areas where it is
exposed to water or damp conditions.
• The LED light strip illuminates the interior of the appliance. It
is not suitable for lighting a room.
• When transporting or operating the appliance at an altitude
of more than 1500 m above sea level, the glass pane in the
door can break due to the reduction in air pressure. Broken
fragments are sharp-edged and can cause serious injury.
6
Climate rating
The climate rating indicates the room temperature at which the
appliance may be operated in order to achieve full refrigeration
performance.
The climate rating is indicated on the type plate.
The position of the type plate is shown in the section entitled
Description of the appliance.
Climate rating
Room temperature
SN
+10 °C to +32 °C
N
+16 °C to +32 °C
ST
+16 °C to +38 °C
SN-ST
+10 °C to +38 °C
T
+16 °C to +43 °C
SN-T
+10 °C to +43 °C
Do not operate the appliance outside the
specified room temperature range.
Setting up
• Avoid positioning the appliance in direct sunlight or near
cookers, radiators and similar sources of heat.
• The floor on which the appliance stands should be horizontal
and level. Compensate for uneven floors with
the adjustable feet.
Do not cover ventilation openings
•
or grill..
• Standard EN 378 specifies that the room in
which you install your appliance must have a
volume of 1 m3 per 8 g of R 600a refrigerant
used in the appliance, so as to avoid the for-
mation of inflammable gas/air mixtures in the
room where the appliance is located in the event
of a leak in the refrigerant circuit. The quantity
of refrigerant used in your appliance is indicated on the type
plate on the inside of the appliance.
• Always install the appliance directly
against the wall.
• Place the appliance in its final position
at the place of installation. Extend the
adjustable foot at the bottom hinge
bracket until it rests on the floor and
then make a further 90° turn.