Absolare Phono Stage Benutzerhandbuch - Seite 9

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Verstärken Absolare Phono Stage herunter. Absolare Phono Stage 13 Seiten.

Custom level is short circuited as factory default.
Input A load levels: 68 Ω, 150 Ω, 330 Ω, 680 Ω, 47 kΩ, (custom installed value)
Input B load levels: 47 Ω, 100 Ω, 220 Ω, 470 Ω, 1 kΩ, (custom installed value)
Input capacitance is fixed at 100pF.
You can use the 47K setting for MM cartridges.

6.2. Installing/Changing Custom Load Resistors

Custom load resistors are accessible from behind the small back cover. First you
should remove the four hex screws on the corners of the small cover on the rear
panel. Then you can change the resistors to any desired value. There are straight
wires in place of the resistors as the factory default.
9
ABSOLARE Phono Stage User Manual 1.2