Make sure that the drain hose is not
kinked or cracked. Avoid leaving the
drain hose in a folded position during
transport and storage.
Drip Tray: Inspect the drip tray.
Clean when dirt and debris are present.
Dirt and debris could clog the funnel
preventing water from draining.
Automatic Pump and Compressor:
Pump and compressor should be
inspected annually.
FEATURES
Rapid Hot Gas Defrost: Swiftly melts
ice formation on the cooling coil and
returns the unit to dehumidification
mode. This occurs in a fraction of the
time compared to a simple fan-defrost
system that can sacrifice more than 25%
of dehumidification operation time.
Compact Design: The overall width of
the unit is four inches (16%) narrower
than competitive units. This is achieved
by the inset wheels, which makes it more
maneuverable, especially through
narrow entryways and staircases.
Removable Heat Exchanger:
Allows for quick, easy cleaning and
maintenance which allows access to the
cooling coil surfaces.
Rugged ABS Skid Panel: Panel makes
loading and unloading simple and
protects the unit from scratches and
abrasions.
Control Panel: The control panel plus
the power and drain hose connections
are nested into the back panel for added
protection and convenience. It features
an hour meter, light indicators to let you
know if the unit is on, in defrost mode, if
pump is engaged or if there is an error.
Hinged Top: Unlike competitive units,
the hinged top prevents loss or
misplacement of the cover. The
detachable power cord and drain hose
Dry Air Technology • 313 North Oak Street Burlington, Washington 98233
Toll Free U.S. & Canada: 888.755.9176 • Tel: 360.755.9176 • Fax: 360.755.9236
store easily inside the hinged top thus
eliminating dangling cords and hoses.
SPECIFICATIONS
Height: 41.1"
Width: 20.4"
Depth: 22.0"
Weight: 142 LBS
AHAM
(80ºF, 60%)
Airflow: 330 CFM
Compressor: 9,165 BTU
Power Supply: 110V
Amperage: 7.4 amps
Refrigerant: R - 22
REPAIRS
1. Should an electrical component fail
consult your Distributor or the
Factory Service Center to obtain
OEM parts.
2. If a problem develops in the
refrigeration system, only a certified
refrigeration technician can correct
it. Contact your Distributor or the
Factory Service Center for more
information.
3. For technical support and general
information, contact your Distributor
or the Factory Service Center.
140 pints
(17.5 gallons)