Dryflow BulletDri Benutzerhandbuch - Seite 5
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Trockner Dryflow BulletDri herunter. Dryflow BulletDri 12 Seiten.
5. Drill four(4) holes at location A,B,C, and D of 5/16" Diameter(Φ8) x 35MM[1-3/8"] deep if using wall
anchors supplied with unit. Install supplied anchors flush with wall face, or install other fastening system
suitable for wall conditions (not supplied). Attach dryer to wall. For wood wall/studs use Dia. M6[1/4"]
screws at length that will ensure 25MM [1"] min. stud penetration. For masonry walls use expansion bolts
or anchors for Dia.M6[1/4"] screws to ensure penetration 6MM[1/4"] deeper than anchor. Shim if
necessary to ensure base plate is flat against wall.
6. Connect supply and ground wires to terminal block where indicated or connect supply wires to
terminal block where indicated and connect ground wire to base plate with ground screw.
A. Connect the live wire(colored Brown, Red, or Black) to the terminal block marked "L".
B. Connect the neutral wire(colored Black, Blue, White or Grey) or connect the second live
wire(colored Red or Orange) to the terminal block marked "N".
C. Connect the ground wire to the terminal block marked
"Bare grounding (earth) wires should be sleeved with green and yellow or green tubing.
"
Colors of live and neutral wires depends on voltage of supply service and requirements of
Building and Electrical Code having jurisdiction.
7. Replace cover. Do not over-tighten screws.
Circuit Breaker [By others]
Connections:
"
Dia.Φ8ΜΜ[5/16"]
4MM [5/32"]
" or to the green screw marked