BASIC USE
Operation without touching,
place your hands under the
exit to activate the device.
OWNER ADJUSTMENTS
It is possible to turn on/off hot air with a
switch(Selection) located inside the unit
chassis [See 7 in "INSTALLATION"].
DIAGNOSTICS & REMEDIES
Hand dryer fails to
start
Hand dryer turns
on/off erratically
or not sensitive
enough
Not hot air
Hand dryer makes
ticking noise
Externally visible service
blue LED light guides
hands to air flow.
Ensure the breaker supplying the dryer is operational. If it is, disconnect the
power and remove the hand dryer cover.
Check all the wire connections to make sure they are well fixed.
Turn on power and verify correct power at terminal block. If it does not work
then replace circuit board.
Ensure that there is no obstruction on or in front of the infrared sensor zone.
Clean any dirt off the sensor lens.
Try adjusting the sensitivity potentiometer on program board.
If it still does not work, replace circuit board and sensor board.
Check if the heat element switch is set for power on.
Check if the heat element is broken. If yes, replace with a new one.
Check the motor brush wear down condition. Replace them if worn out or
install a new motor.
Disconnect power, remove cover, check to make sure no object is stuck in
motor vents.
After 3 seconds without
detecting hands, the device
stops automatically.
It is possible to adjust the sensor range by
means of the sensor VR located on program
PCB [See section 8 in "INSTALLATION"].