Daintree GE Current Arize Factor Installationshandbuch - Seite 9
Blättern Sie online oder laden Sie pdf Installationshandbuch für Beleuchtungsanlagen Daintree GE Current Arize Factor herunter. Daintree GE Current Arize Factor 10 Seiten. Horticulture led lighting system
Arize
Factor
®
Wired Dimming Connections (Optional)
RISK OF ELECTRIC SHOCK
• Turn power off before installation, inspection, cleaning or removal.
And follow appropriate lock out/tag out safety procedure.
• This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and
operation of the product and the hazards involved.
Remove screws
1
Junction Box Cover Removal
• Using a #1 Phillips screwdriver, unscrew the 6
screws on the junction box cover.
• Remove the junction box cover from the junction
box enclosure.
NOTE: Be sure to hold on to the screws, junction box
cover, and gasket for future use.
Dimming
Switch
+ (0-10V)
- (0-10V)
Wire Dimming Electrical Connection
3
Connect the appropriate wiring to Dim + (0-10V) and
Dim - (0-10V) from driver. Insulate the black, pink &
blue wires. Follow dimming switch instructions for rest
of connection.
WARNING / AVERTISSEMENT
RISQUE DE CHOC ELECTRIQUE
• Coupez l'alimentation avant l'inspection, l'installation ou la
• Ce produit doit être installé selon le code d'installation pertinent, par
Remove cover
Driver
Black
Pink
Blue
Violet
Gray
désinstallation.
une personne qui connaît bien le produit et son fonctionnement ainsi
que les risques inhérents.
AC input
2
Wall Dimming Wire Insertion
• Remove the sealed gland in the bottom of the
junction box enclosure, and install an appropriate
Listed ½" NPT fitting rated for the environment into
the open threaded open conduit connection.
• Bring the conductors for the building dimming
network into this fitting.
NOTE: Customer is responsible for the 1/2'' NPT- 14
thread per inch fitting.
Gasket in cover
Junction Box Cover Replacement
4
• Ensure gasket is sitting in place on the inner edge of
the junction box cover.
• Fasten all 6 screws to ensure water tight seal.
NOTE: Be careful not to strip out the junction box
enclosure by over tightening the screws.
9
Installation Guide
To lightbar
Dimming In